User guide
Open Problem Reports and Feature Exceptions
OmniSwitch 6600/7000/8800—Release 5.1.6.R02 page 41
PR 84618
The Policy > Policy > Ports Modify window, returns the error message, "Port enable/disable is not
supported”, whenever one tries to make a change.
Workaround: Manually set the "Enabled" field to a blank during modification and continue with the rest
of the changes.
PR 84635
WebView may sort some numerical columns incorrectly. For example, the HRE tables sorted by the firm-
ware revision.
Workaround: There is no known workaround at this time.
PR 84677
On an OS6600 series switch, the ACE server should not be listed on available accounting/authentication
servers since it is not supported.
Workaround: There is no known workaround at this time. It is only cosmetic.
PR 85654
CLI allows one to configure read-write for Spanning Tree under EUPM. Functionally, one can only
configure read-only. WebView reflects this properly.
Workaround: The read-write and read-only options behave in a similar manner.
PR 87960
Sometimes WebView doesn't refresh the Source Learning table properly causing submission failed when
trying to delete a MAC.
Workaround: Press the refresh button before performing MAC address deletion.
PR 88765
On an OS7000 series switch, WebView's system management switch logging tech-support page does not
have provisions for dumping RIPng configuration information.
Workaround: Technical support logs created using CLI gives the user an option to dump RIPng.
PR 88942
On an OS8800 switch, an IPv6 default route to the configuration cannot be added using WebView.
Workaround: Add the IPv6 default route to the configuration using CLI.