User guide
Open Problem Reports and Feature Exceptions
OmniSwitch 6600/7000/8800—Release 5.1.6.R02 page 37
PR 71891
When adding an accept action on an OS7000 series switch using the Actions > ACL page, if no SLB clus-
ter is provided, the just added action will not show up on the Actions > ACL table. (However, it will be
displayed in the Actions > All table.)
Workaround: Go to the Actions > All table.
PR 75312
If an external authentication server has a user name that's spelled exactly like a local user on a switch, the
option link still appears, even though the switch is authenticated through the external server.
Workaround: Use different user names.
PR 76783
When one clicks on the column header of a table with the SHIFT key held down, an empty browser
window opens. This is because column headers are functionally HTML links, and the programmed
browser behavior is to open up a link in a new browser window when the SHIFT key is held down.
Workaround: Don't hold the SHIFT key down when clicking on the column header.
PR 77106
The user is randomly unable to re-login to WebView on Netscape 4.7x.
Workaround: Close the browser and open a new window.
PR 77279
On an OS6000 series switch in WebView Physical - Health - LED Status, information is incorrect in the
table. There should not be two columns for the same module. The Physical Name contains unuseful data.
The Primary CMM should say "Green On", the Temperature and the Fan should say "Green(OK)".
Workaround: Ignore the extra column and the Physical Name row. Use CLI for the correct status of the
Primary/Secondary CMM, Temperature, and Fan.
PR 78032
On an OS7000 series switch, an error displays when clicking on a menu that doesn't have submenus before
the home page is completely loaded.
Workaround: Wait until the home page is fully loaded, and then click on the menu for the selected table /
page to view. [Currently, there is no way to detect from a browser (except IE—even then, the function is
not fully reliable) when a specific page is fully loaded in order to force a wait.] If an error displays, refresh
by clicking on the left-hand side feature icon.