User guide

Open Problem Reports and Feature Exceptions
OmniSwitch 6600/7000/8800—Release 5.1.6.R02 page 31
PR 50089/53442
When a GetNext request is sent on any object of the trapConfigTable, sessionConfigTable, or trapFilter-
Table, and if the index value is equal to 4294967295, then the agent does not respond as expected; i.e. the
object returned is not lexicographically larger on an OS7000 series switch.
Workaround: There is no known workaround at this time.
PR 50404
Our system treats user name "admin" differently from other user names. It is defined for our system with-
out SNMP access. This cannot be modified.
Workaround: There is no known workaround at this time.
PR 53289
Flood multicast changes on an OS7000 series switch are applicable for all the ports in that slot.
Workaround: In order to change the flood multicast value, chose any ifIndex for that slot and change the
value. The change will be applicable for all the ports in that slot.
PR 53817
Session Inactivity settings do not affect active sessions on an OS7000 series switch. Only new sessions
use the changed settings.
Workaround: Disconnect all active sessions and reconnect to the switch.
PR 79611
On an OS7000 series switch, the SNMP Agent does not respond to discover requests when the packet has
an unknown user id.
Workaround: There is no known workaround at this time.
PR 80197
On an OS7000 series switch, the SNMP Agent fails to increment snmpInASNParseErrs for PDUs with
invalid ASN.1 BER encoding.
Workaround: There is no known workaround at this time.
PR 81409
On OS6600 series switches, the SNMP Agent fails to properly handle invalid msgID value.
Workaround: There is no known workaround at this time.