User guide
Open Problem Reports and Feature Exceptions
OmniSwitch 6600/7000/8800—Release 5.1.6.R02 page 29
PR 69058
The admin down CLI command on an OS7-GNI-U2 or OS6-GNI-U2 port does not bring the link down
on the remote end.
Workaround: Unplug the port.
PR 77445
The write terminal and show configuration snapshot output may be lost when using Windows 2000
telnet to connect to a switch.
Workaround: Use Unix, Windows NT, or Windows XP to connect to the switch.
PR 83127
A DoS attack on port 23 (Telnet) results in the message "[CLISHELL 32] Error on setting tty options at
password(851971)” on an OS7000 series switch.
Workaround: The issue is cosmetic and does not effect performance of the switch.
PR 87642
The CLI command to specifically disable 802.1x or AVLAN authentication on a port disables either of the
authentication options configured on the port of an OS6600/OS7000 series switch.
Workaround: There is no known workaround at this time.
PR 88606
Quotes must be used for special characters in a password and exclamation marks are not allowed.
Workaround: There is no known workaround at this time.
PR 90479
On an OS7000 series switch, WebView uses the encapsulation 'ETHERNET2' only; to avoid confusion,
the redundant encapsulation 'E2' has been removed from the CLI command. The 'ETHERNET2' encapsu-
lation remains.
Workaround: There is no known workaround at this time.