User guide

Open Problem Reports and Feature Exceptions
OmniSwitch 6600/7000/8800—Release 5.1.6.R02 page 103
PR 75615
On an OS6600 series switch, a "continuous Flash synchro" process may occur if the local "working" and
"certified" directories are not "certified".
Workaround: When any stacks are required to be connected to other stacks, make sure the individual
stacks are synchronized between themselves locally (Working and Certified) and within each module of
the current stack environment.
PR 76349
On an OS7000 series switch, admin down on a port cannot bring down the link on the link partner. As a
result, the link partner can detect LINK UP or toggling UP and DOWN.
Workaround: There is no known workaround at this time.
PR 76500
Flash File System may become corrupt after the Certify, Restore, or Flash Synchro process.
Workaround: There is no known workaround at this time.
PR 76658
MAC Server manager has a maximum range of 256 MACs. If the system is configured with a MAC range
exceeding 256 MACs, the MAC server is not consistent. The MAC range EEPROM CLI command rejects
the command if the MAC count exceeds 256.
Workaround: Reconfigure the MAC-range EEPROM to be 256 MACs or less.
PR 79859
Firmware version is not shown using SNMP on an OS7000 series switch.
Workaround: There is no known workaround at this time.
PR 80937
IPC buffers can be used up by VLAN Manager on an OS8800 switch, when a bootup or CMM takeover
occurs.
Workaround: There is no known workaround at this time.
PR 82675
If the boot flag is set to 0x40000, then it causes the tssApp task to crash when attempting to execute some
CLI commands on an OS7000 or OS6600 series switch.