SMS 7000 Release Notes 27
Hardware, Firmware, and Software Installation
MCPU Network Parameters Configuration
This is to be used when upgrading from versions 3.x and 4.x only.
If not already connected, connect a dumb terminal to the system CTL port.
It is necessary to configure your MCPU network parameters to allow prop-
er communication of network devices such as the GUI PC.
Verify that the left MCPU (MCPU #1) is up and running as primary (yellow
LED on). (If not, type switchmcpu at the diagnostic terminal Series 7000
prompt to switchover to the left MCPU.) At the diagnostic terminal type:
SMS7000> booted
This starts the boot parameter editor. Current boot parameters will be dis-
played with the cursor positioned ready for your input.
If the boot parameter is correct, press RETURN to skip it. If it is not correct,
enter the desired value. Verify that your primary MCPU(s) boot parameters
match those below. Boot parameters for the secondary MCPU are in brack-
ets [ ] to the right of the values for the primary. Pay particular attention to
the inet on ethernet field and the target name field.
boot device: fi
processor number: 0
host name: PC
file name: SMS
net on ethernet (e): 192.0.2.2[192.0.2.3]
inet on backplane (b): 192.0.3.4
host inet (h): 192.0.2.1
gateway inet (g):
user (u): smsuser
ftp password (p): smsuser
flags (f): 0x8
target name (tn): sms7000[sms7000b]
startup script:
other (o): sl (for SLIP) ei (for Ethernet)
After verifying the boot parameters for the primary MCPU, type
switchmcpu at the sms7000 prompt and repeat booted for the secondary
MCPU. After verifying boot parameters on the secondary MCPU, type
switchmcpu again to allow the master MCPU to run as primary.