Specifications
SMS 7000 Release Notes 19
Hardware, Firmware, and Software Installation
2. Telnet into the System Diagnostic Interface.
Enter the following command:
For MCPU #1
C:\> telnet sms7000
For MCPU #2
C:\> telnet sms7000b
3. Press
RETURN
to
see the SMS7000> System Diagnostic prompt.
4. Enter the following commands at the System Diagnostic prompt:
SMS7000> del “slip.ini”
SMS7000> del “console.ini”
5. Verify the above files have been deleted by examining a directory
listing of the FLASH file system.
Enter the dir command:
SMS7000> dir
The files just deleted should NOT exist in the FLASH file system direc-
tory.
Exit the Telnet program by typing logout
SMS7000> logout
CAUTION
If you do not properly EXIT Telnet (logout), you will not be able to re-estab-
lish Telnet communication except by RESETTING the MCPU(s).
6. Remove the MCPU(s) from the frame. Remove the top Amezi
mezzanine and replace it with a UART mezzanine board. Re-insert the
MCPU(s). Both mezzanines must now be UART mezzanines.
7. Verify that the System Diagnostic Interface (SMS7000> prompt) is now
running on the CTL port of the Compact 64V. (Native Protocol is no
longer running.) The communications parameters are as follows:
RS232 9600 baud 8 data bits Parity = None 1 stop bit.