User manual

1–Switch Management Classes
QLGC_LogicalIOBlade : CIM_LogicalIOBlade
59223-03 E 1-21
Parameters:
RequestedState [required] Parameter must be one of
the following enumerated values.
2-Enabled: Blade is online.
3-Disabled: Blade is offline
7-Test: Blade is in diagnostics mode.
11-Reset: Blade will be reset.
32768-PoweredOff: Blade will be powered off,
and the CIMAgent will no longer report the blade
object until is it powered on again (or
re-inserted).
Job Ignored, command is synchronous.
TimeoutPeriod, must be zero second interval, or NULL,
command is synchronous.
Method Returns:
0 - Success
6 - In Use: Switch is being configured by another user.
4097 - Invalid State: Transition
RequestedState: parameter value is out of range, or
currently not supported by the blade.
4098 – Use of Timeout Parameter Not Supported
Request Status Codes:
CIM_ERR_ACCESS_DENIED: User does not have
authorization for this command.
CIM_ERR_INVALID_PARAMETER: One or more
required parameters are missing.
CIM_ERR_NOT_FOUND: The LogicalModule instance
was not found.
Supported WBEM Operations
getClass
getInstance
enumerateInstances
enumerateInstanceNames