QUICK START GUIDE [ Quick Start Guide ] SilverStorm™ 9040 INSTALLATION d
Purchasers of OEM products should consult with the OEM for support. Support Headquarters QLogic Corporation 4601 Dean Lakes Blvd Shakopee, MN 55379 QLogic Web Site www.qlogic.com Technical Support Web Site support.qlogic.com Technical Support Email support@qlogic.com Technical Training Email tech.training@qlogic.com North American Region Email support@qlogic.com Phone +1 952-932-4040 Fax +1 952-932-4018 All other regions of the world QLogic Web Site www.qlogic.
SilverStorm 9040 Quick Start Guide Pre-Installation Checklist Before beginning the actual installation, the Site Implementation Engineer must perform the following tasks: Step 1. Check the packing list to verify all ordered equipment has been received. The box should contain: ❑ ❑ A SilverStorm 9040 switch with the following pre-installed: ❑ Two (2) fan units ❑ Power supplies and blanks (4 total).
Step 4. Verify that the equipment shipped matches the packing list. Tools and Equipment Required ❑ An ESD wrist strap ❑ A #2 Phillips screwdriver ❑ Pen (felt-tip) to mark the mounting holes on the rack Installation Tasks To perform the actual switch installation, the site implementation engineer must perform the following tasks, which are detailed in this section. Step 1. Check the installation site to verify the installation of cabinet power feeds, rails, and grounding. Step 2.
Changing the IP Address and Default Gateway Using the RS232 Serial Port Step 1. Connect null-modem/crossover serial cables to the RS-232 port of the switch spine module. If using a terminal emulation device, the settings should be: ❑ 8 data bits ❑ no parity bits ❑ 1 stop bit ❑ 56K baud ❑ Use VT100 emulation. ❑ Flow control = XON/XOFF Step 2. Power up the switch. Step 3.
Step 4. The system prompts for a user name. In order to change the IP address and default gateway, the user must be logged in as the administrator. At the prompt enter: admin Step 5. The system prompts for a password. At the prompt enter: adminpass The system responds with: Welcome to the SilverStorm 9040 CLI. Type 'list' for the list of commands. Step 6.
Step 4. From the main menu select OOB LAN IP then Set OOB LAN IP. The following screen is displayed: Figure 1. Set OOB LAN IP Window Step 5. Type in the new switch IP address. Step 6. Type in the new net mask. Step 7. Click Apply. Step 8. To change the switch default gateway, from the main menu select OOB LAN IP then Set Default Gateway IP. The following screen is displayed: Figure 2. Set Default Gateway IP Window Step 9. Type in the correct switch default gateway IP address. Step 10. Click Apply.
Installing Documentation from a CD Installing Documentation on a Linux Host Step 1. Place the Documentation CD in the CD-ROM drive. Step 2. Check that the CD has been mounted. Type ls /mnt/cdrom. The system returns a list of files on the CD. Step 3. reside. Create a subdirectory on the drive where the documentation will Step 4. Type cp /mnt/cdrom/ / to copy the documentation to the subdirectory created in Step 3. Step 5. file.
Declaration of Conformity QLogic Corporation. 26650 Aliso Viejo Parkway Aliso Viejo, CA 92656 Phone: 949.389.6000 www.qlogic.com QLogic Corporation declares the following product is in compliance with the following standards.
8
© 2007 QLogic Corporation. QLogic, the QLogic logo, the Powered by QLogic logo, SANbox, SANsurfer, and SANsurfer Management Suite are registered trademarks or trademarks of QLogic Corporation. All other brands and product names are trademarks or registered trademarks of their respective owners. Information supplied by QLogic is believed to be accurate and reliable. QLogic Corporation assumes no responsibility for any errors in this brochure.
J QLogic Corporation 949.389.6000 26650 Aliso Viejo Parkway www.qlogic.com Aliso Viejo, CA 92656 D000010-004 Rev.