user manual
Table Of Contents
- Table of Contents
- Section 1 Introduction
- Section 2 Command Line Interface Usage
- Section 3 User Account Configuration
- Section 4 Network and Fabric Configuration
- Section 5 Switch Configuration
- 5.1 Displaying Switch Information
- 5.2 Managing Switch Services
- 5.3 Managing Switch Configurations
- 5.4 Paging a Switch
- 5.5 Setting the Date and Time
- 5.6 Resetting a Switch
- 5.7 Installing Firmware
- 5.8 Managing Switch Feature Upgrades
- Section 6 Port Configuration
- Section 7 Zoning Configuration
- Section 8 Connection Security Configuration
- Section 9 Device Security Configuration
- Section 10 RADIUS Server Configuration
- Section 11 Event Log Configuration
- Section 12 Simple Network Management Protocol Configuration
- Section 13 Command Reference
- 13.1 Access Authority
- 13.2 Syntax and Keywords
- 13.3 Notes and Examples
- 13.4 Command Listing
- Admin
- Alias
- Config
- Create
- Date
- Exit
- Fcping
- Fctrace
- Feature
- Firmware Install
- Group
- Hardreset
- Help
- History
- Hotreset
- Image
- Lip
- Logout
- Passwd
- Ping
- Ps
- Quit
- Reset
- Security
- Securityset
- Set Alarm
- Set Beacon
- Set Config Port
- Set Config Security
- Set Config Security Portbinding
- Set Config Switch
- Set Config Threshold
- Set Config Zoning
- Set Log
- Set Pagebreak
- Set Port
- Set Setup Radius
- Set Setup Services
- Set Setup SNMP
- Set Setup System
- Set Switch State
- Set Timezone
- Show About
- Show Alarm
- Show Broadcast
- Show Chassis
- Show Config Port
- Show Config Security
- Show Config Security Portbinding
- Show Config Switch
- Show Config Threshold
- Show Config Zoning
- Show Domains
- Show Donor
- Show Fabric
- Show FDMI
- Show Interface
- Show Log
- Show LSDB
- Show Media
- Show Mem
- Show NS
- Show Pagebreak
- Show Perf
- Show Port
- Show Post Log
- Show Setup Mfg
- Show Setup Radius
- Show Setup Services
- Show Setup SNMP
- Show Setup System
- Show Steering
- Show Switch
- Show Timezone
- Show Topology
- Show Users
- Show Version
- Shutdown
- Test Cancel
- Test Port
- Test Status
- Uptime
- User
- Whoami
- Zone
- Zoneset
- Zoning
- Index

5 – Switch Configuration
Paging a Switch
59183-01 A 5-17
A
5.4
Paging a Switch
To help you locate a particular switch in a rack of switches, you can turn on the
beacon feature with the Set Beacon command. This causes all port Logged-In
LEDs to flash in unison. The following is an example of how to turn the beacon on
and off.
SANbox #> set beacon on
SANbox $> set beacon off
5.5
Setting the Date and Time
The switch date and time can be set explicitly using the Date command or it can
be set automatically through a Network Time Protocol (NTP) server. The Date
command also displays the current time. Unlike the Date command, the NTP
server also synchronizes the date and time on the switch with the date and time
on the workstation. Synchronized date and time is required for Secure Socket
Layer (SSL) connections.
You can also set the time zone using the Set Timezone command. The default
time zone is Universal Time (UTC) also known as Greenwich Mean Time.
Changing the time zone also converts the current time to the time in the new time
zone. For this reason, if you are not using an NTP server, set the time zone first,
then set the date and time.
To use an NTP server, you must enable the NTP client on the switch and specify
an IP address for the NTP server.
NOTE: To set the date with the Date command, the NTP client must be
disabled.