user manual
Table Of Contents
- Table of Contents
- Section 1 Introduction
- Section 2 Command Line Interface Usage
- Section 3 User Account Configuration
- Section 4 Network and Fabric Configuration
- Section 5 Switch Configuration
- 5.1 Displaying Switch Information
- 5.2 Managing Switch Services
- 5.3 Managing Switch Configurations
- 5.4 Paging a Switch
- 5.5 Setting the Date and Time
- 5.6 Resetting a Switch
- 5.7 Installing Firmware
- 5.8 Managing Switch Feature Upgrades
- Section 6 Port Configuration
- Section 7 Zoning Configuration
- Section 8 Connection Security Configuration
- Section 9 Device Security Configuration
- Section 10 RADIUS Server Configuration
- Section 11 Event Log Configuration
- Section 12 Simple Network Management Protocol Configuration
- Section 13 Command Reference
- 13.1 Access Authority
- 13.2 Syntax and Keywords
- 13.3 Notes and Examples
- 13.4 Command Listing
- Admin
- Alias
- Config
- Create
- Date
- Exit
- Fcping
- Fctrace
- Feature
- Firmware Install
- Group
- Hardreset
- Help
- History
- Hotreset
- Image
- Lip
- Logout
- Passwd
- Ping
- Ps
- Quit
- Reset
- Security
- Securityset
- Set Alarm
- Set Beacon
- Set Config Port
- Set Config Security
- Set Config Security Portbinding
- Set Config Switch
- Set Config Threshold
- Set Config Zoning
- Set Log
- Set Pagebreak
- Set Port
- Set Setup Radius
- Set Setup Services
- Set Setup SNMP
- Set Setup System
- Set Switch State
- Set Timezone
- Show About
- Show Alarm
- Show Broadcast
- Show Chassis
- Show Config Port
- Show Config Security
- Show Config Security Portbinding
- Show Config Switch
- Show Config Threshold
- Show Config Zoning
- Show Domains
- Show Donor
- Show Fabric
- Show FDMI
- Show Interface
- Show Log
- Show LSDB
- Show Media
- Show Mem
- Show NS
- Show Pagebreak
- Show Perf
- Show Port
- Show Post Log
- Show Setup Mfg
- Show Setup Radius
- Show Setup Services
- Show Setup SNMP
- Show Setup System
- Show Steering
- Show Switch
- Show Timezone
- Show Topology
- Show Users
- Show Version
- Shutdown
- Test Cancel
- Test Port
- Test Status
- Uptime
- User
- Whoami
- Zone
- Zoneset
- Zoning
- Index

13 – Command Reference
Show Switch
59183-01 A 13-141
A
Show Switch
Displays switch operational information.
Authority None
Syntax show switch
Notes Table 13-27 describes the switch operational parameters.
Table 13-27. Switch Operational Parameters
Parameter Description
SymbolicName Descriptive name for the switch
SwitchWWN Switch world wide name
BootVersion PROM boot version
CreditPool Number of port buffer credits available to recipient
ports
DomainID Switch domain ID
FirstPortAddress FC address of switch port 0
FlashSize - MBytes Size of the flash memory in megabytes
LogFilterLevel Event severity level used to record events in the
event log
MaxPorts Number of ports available on the switch
NumberOfSwitchResets Number of times the switch has been reset over its
service life
ReasonForLastReset Action that caused the last reset
ActiveImageVersion - build date Active firmware image version and build date.
PendingImageVersion - build date Firmware image version and build date that is
pending. This image will become active at the next
reset or power cycle.
ActiveConfiguration Name of the switch configuration that is in use.
AdminState Switch administrative state
AdminModeActive Admin session status
Beacon Beacon status as set by the Set Beacon com-
mand.
OperationalState Switch operational state