user manual
Table Of Contents
- Table of Contents
- Section 1 Introduction
- Section 2 Command Line Interface Usage
- Section 3 User Account Configuration
- Section 4 Network and Fabric Configuration
- Section 5 Switch Configuration
- 5.1 Displaying Switch Information
- 5.2 Managing Switch Services
- 5.3 Managing Switch Configurations
- 5.4 Paging a Switch
- 5.5 Setting the Date and Time
- 5.6 Resetting a Switch
- 5.7 Installing Firmware
- 5.8 Managing Switch Feature Upgrades
- Section 6 Port Configuration
- Section 7 Zoning Configuration
- Section 8 Connection Security Configuration
- Section 9 Device Security Configuration
- Section 10 RADIUS Server Configuration
- Section 11 Event Log Configuration
- Section 12 Simple Network Management Protocol Configuration
- Section 13 Command Reference
- 13.1 Access Authority
- 13.2 Syntax and Keywords
- 13.3 Notes and Examples
- 13.4 Command Listing
- Admin
- Alias
- Config
- Create
- Date
- Exit
- Fcping
- Fctrace
- Feature
- Firmware Install
- Group
- Hardreset
- Help
- History
- Hotreset
- Image
- Lip
- Logout
- Passwd
- Ping
- Ps
- Quit
- Reset
- Security
- Securityset
- Set Alarm
- Set Beacon
- Set Config Port
- Set Config Security
- Set Config Security Portbinding
- Set Config Switch
- Set Config Threshold
- Set Config Zoning
- Set Log
- Set Pagebreak
- Set Port
- Set Setup Radius
- Set Setup Services
- Set Setup SNMP
- Set Setup System
- Set Switch State
- Set Timezone
- Show About
- Show Alarm
- Show Broadcast
- Show Chassis
- Show Config Port
- Show Config Security
- Show Config Security Portbinding
- Show Config Switch
- Show Config Threshold
- Show Config Zoning
- Show Domains
- Show Donor
- Show Fabric
- Show FDMI
- Show Interface
- Show Log
- Show LSDB
- Show Media
- Show Mem
- Show NS
- Show Pagebreak
- Show Perf
- Show Port
- Show Post Log
- Show Setup Mfg
- Show Setup Radius
- Show Setup Services
- Show Setup SNMP
- Show Setup System
- Show Steering
- Show Switch
- Show Timezone
- Show Topology
- Show Users
- Show Version
- Shutdown
- Test Cancel
- Test Port
- Test Status
- Uptime
- User
- Whoami
- Zone
- Zoneset
- Zoning
- Index

13 – Command Reference
Set Setup SNMP
13-90 59183-01 A
S
Set Setup SNMP
Configures SNMP on the switch.
Authority Admin session
Syntax set setup snmp
Prompts you in a line-by-line fashion to change SNMP configuration settings.
Table 13-22 describes the SNMP fields. For each parameter, enter a new value or
press the Enter key to accept the current value shown in brackets.
Table 13-22. SNMP Configuration Settings
Entry Description
SNMPEnabled Enables (True) or disables (False) SNMP on the switch. The
default is True.
Contact Specifies the name of the person to be contacted to respond to
trap events. The name can be up to 64 characters excluding #,
semicolon (;), and comma (,). The default is undefined.
Location Specifies the name of the switch location. The name can be up
to 64 characters excluding #, semicolon (;), and comma (,).
The default is undefined.
Trap [1-5] Address Specifies the workstation IP address to which SNMP traps are
sent. The default address for trap 1 is 10.0.0.254. The default
address for traps 2–5 is 0.0.0.0. Addresses, other than 0.0.0.0,
for all traps must be unique.
Trap [1-5] Port Specifies the workstation port to which SNMP traps are sent.
Valid workstation port numbers are 1–65535. The default is
162.
Trap [1-5] Severity Specifies the severity level to use when monitoring trap events.
The default is Warning.
Trap [1-5] Version Specifies the SNMP version (1 or 2) to use in formatting traps.
The default is 2.
Trap [1-5] Enabled Specifies whether traps (event information) are enabled or dis-
abled (default).
ReadCommunity Read community password that authorizes an SNMP agent to
read information from the switch. This is a write-only field. The
value on the switch and the SNMP management server must
be the same. The read community password can be up to 32
characters excluding #, semicolon (;), and comma (,). The
default is “public”.