Cut Sheet

α
[% / K] + 0.04
β
[% / K] − 0.27
γ
[% / K] − 0.36 NMOT [°F] 109 ± 5.4 (43 ± 3 °C)
[W] 340 345 [A] 10.02 10.07
[A] 10.52 10.58 [V] 33.94 34.25
[V] 40.66 40.92 [%] ≥ 19.0 ≥ 19.3
[V] 1000 Class II
[A DC] 20 TYPE 2
[lbs / ft
2
] 75 (3600 Pa) / 55 (2667 Pa)
− 40 °F up to + 185 °F
(− 40 °C up to + 85 °C)
[lbs / ft
2
] 113 (5400 Pa) / 84 (4000 Pa)
3
See Installation Manual
26
28
26
70.1 × 42.5 × 47.6 in (1780 × 1080 × 1208 mm)
1310 lbs (594 kg)
Hanwha Q CELLS America Inc.
400 Spectrum Center Drive, Suite 1400, Irvine, CA 92618, USA | TEL +1 949 748 59 96 | EMAIL inquiry@us.q-cells.com | WEB www.q-cells.us
[VA] 295
5.8 Arms
[VA] 290 13
[V] 240 / 211 ~ 264 III
[A] 1.21 18 mA
[Hz] 60 1
[Hz] 47 - 68 0.85 leading ... 0.85 lagging
Certified
UL 1703
(254141)
MECHANICAL SPECIFICATIONS
Format
68.5 × 40.6 × 1.57 in (including frame)
(1740 × 1030 × 40 mm)
Weight 47.2 lbs (21.4 kg)
Front Cover 0.13 in (3.2 mm) thermally pre-stressed glass
with anti-reflection technology
Back Cover Composite film
Frame Black anodized aluminum
Cell 6 × 20 monocrystalline Q.ANTUM solar half cells
Junction Box 2.09-3.98 × 1.26-2.36 × 0.59-0.71 in (53-101 × 32-60 × 15-18 mm),
Protection class IP67, with bypass diodes
Cable 4 mm² Solar cable; (+) ≥ 45.3 in (1150 mm), (−) ≥ 33.5 in (850 mm)
Connector Stäubli MC4; IP68
Note: Installation instructions must be followed. See the installation and operating manual or contact our technical service department for further information on approved installation and use
of this product.
Specifications subject to technical changes © Q CELLS Q.PEAK DUO BLK-G6+_AC_340-345_2020-07_Rev01_NA
DC ELECTRICAL CHARACTERISTICS
POWER CLASS 340 345 340 345
MINIMUM PERFORMANCE AT STANDARD TEST CONDITIONS, STC
1
(POWER TOLERANCE +5 W / −0 W)
Min. Power at MPP
1
P
MPP
Min. Current at MPP I
MPP
Min. Short Circuit Current
1
I
SC
Min. Voltage at MPP V
MPP
Min. Open Circuit Voltage
1
V
OC
Min. Efficiency
1
η
1
Measurement tolerances P
MPP
± 3 %; I
SC
; V
OC
± 5 % at STC: 1000 W/m
2
, 25 ± 2 °C, AM 1.5 according to IEC 60904-3
Q CELLS PERFORMANCE WARRANTY PERFORMANCE AT LOW IRRADIANCE
At least 98 % of nominal power during
first year. Thereafter max. 0.54 %
degradation per year. At least 93.1 %
of nominal power up to 10 years. At
least 85 % of nominal power up to
25 years.
All data within measurement toleranc-
es. Full warranties in accordance with
the warranty terms of the Q CELLS
sales organization of your respective
country.
Typical module performance under low irradiance conditions in
comparison to STC conditions (25 °C, 1000 W/)
TEMPERATURE COEFFICIENTS
Temperature Coefficient of I
SC
Temperature Coefficient of V
OC
Temperature Coefficient of P
MPP
Nominal Module Operating Temperature
PROPERTIES FOR DC SYSTEM DESIGN
Maximum System Voltage V
SYS
PV Module Classification
Maximum Series Fuse Rating Fire Rating based on ANSI / UL 1703
Max. Design Load, Push / Pull
3
Permitted Module Temperature
on Continuous Duty
Max. Test Load, Push / Pull
3
QUALIFICATIONS AND CERTIFICATES PACKAGING INFORMATION
Solar module: UL 1703,
U.S. Patent No. 9,893,215 (solar cells);
Enphase micro inverter: UL 1741-SA, UL 62109-1,
UL1741/IEEE1547, FCC Part 15 Class B,
ICES-0003 Class B, CAN/CSA-C22.2 NO. 107.1-01,
Rapid Shutdown Compliant per NEC-2014
& 2017 & C22.1-2015
Number of Modules per Pallet
Number of Pallets per Trailer (24 t)
Number of Pallets per 40' HC-Container (26 t)
Pallet Dimensions (L × W × H)
Pallet Weight
200 400 600 800 1000
110
100
90
80
RELATIVE EFFICIENCY [%]
IRRADIANCE [W/m²]
EN
RELATIVE EFFICIENCY
COMPARED TO NOMINAL POWER [%]
100
95
90
85
80
75
155 25200 10
YEARS
98
Q CELLS
Industry standard for tiered warranties
*
Industry standard for linear warranties
*
*
Standard terms of guarantee for the 10 PV companies
with the highest production capacity in 2014 (as at: September 2014)
NA
DETAIL A
0.630" (16 mm)
0.335" (8.5 mm)
0.965" (24.5 mm)
38.58" (980 mm)
68.5" (1740 mm)
4 × Mounting slots (DETAIL A)
Frame
40.5" (1030 mm)
38.62" (981 mm)
1.57" (40 mm)
8 × Drainage holes
15.0“ (380 mm)
4 × Grounding points ø 0.177" (4.5 mm)
Label
AC OUTPUT ELECTRICAL CHARACTERISTICS
IQ7PLUS-72-ACM-US OR IQ7PLUS-72-E-ACM-US
Peak Output Power
AC Short Circuit Fault Current over 3 Cycles
Max. Continuous Output Power Max. Units per 20 A (L-L) Branch Circuit
Nominal (L-L) Voltage / Range Overvoltage Class AC Port
Max. Continuous Output Current AC Port Backfeed Current
Nominal Frequency Power Factor Setting
Extended Frequency Range Power Factor (adjustable)