Cut Sheet

DETAIL A
16 mm
8.5 mm
21.25 mm
980 mm
1717 mm
4 × Mounting slots
(DETAIL A)
Frame
1045 mm
32 mm
8 × Drainage holes
368.5 mm
EN
4 × Grounding points ø 4.5 mm
Label
1150 mm
1150 mm
1002.5 mm
EN
RELATIVE EFFICIENCY
COMPARED TO NOMINAL POWER [%]
YEARS
Q CELLS
Industry standard for linear warranties
*
*
Standard terms of guarantee for the 10 PV companies
with the highest production capacity in 2014 (as at: September 2014)
100
95
90
85
80
155 25200 10
98
86
200 400 600 800 1000
110
100
90
80
RELATIVE EFFICIENCY [%]
IRRADIANCE [W/m²]
α
[% / K] +0.04
β
[% / K] −0.27
γ
[% / K] 0.34 NMOT C] 43 ± 3
[V] 1000
[A] 20 C / TYPE 2
[Pa] 3600 / 2660
−40 °C - +85 °C
[Pa] 5400 / 4000
350 355 360 365 370
[W] 350 355 360 365 370
[A] 10.97 11.00 11.04 11.07 11.10
[V] 41.11 41.14 41.18 41.21 41.24
[A] 10.37 10.43 10.49 10.56 10.62
[V] 33.76 34.03 34.31 34.58 34.84
[%] ≥ 19.5 ≥ 19.8 ≥ 20.1 ≥ 20.3 ≥ 20.6
[W] 262.6 266.3 270.1 273.8 27 7.6
[A] 8.84 8.87 8.89 8.92 8.95
[V] 38.77 38.80 38.83 38.86 38.90
[A] 8.14 8.20 8.26 8.31 8.37
[V] 32.24 32.48 32.71 32.94 33.17
Hanwha Q CELLS GmbH
Sonnenallee 17-21, 06766 Bitterfeld-Wolfen, Germany | TEL +49 (0)3494 66 99-23444 | FAX +49 (0)3494 66 99-23000 | EMAIL sales@q-cells.com | WEB www.q-cells.com
Note: Installation instructions must be followed. See the installation and operating manual or contact our technical service department for further information on approved installation and
use of this product.
Q CELLS PERFORMANCE WARRANTY PERFORMANCE AT LOW IRRADIANCE
At least 98 % of nominal power dur-
ing first year. Thereafter max. 0.5 %
degradation per year. At least 93.5 %
of nominal power up to 10 years. At
least 86 % of nominal power up to
25years.
All data within measurement toler-
ances. Full warranties in accordance
with the warranty terms of the
Q CELLS sales organisation of your
respective country.
Typical module performance under low irradiance conditions in
comparison to STC conditions (25 °C, 1000 W/m
2
).
Specifications subject to technical changes © Q CELLS Q.PEAK DUO BLK-G10+_350-370_2021-08_Rev01_EN
PROPERTIES FOR SYSTEM DESIGN
Maximum System Voltage V
SYS
PV module classification Class II
Maximum Reverse Current I
R
Fire Rating based on ANSI / UL 61730
Max. Design Load, Push / Pull
Permitted Module Temperature
on Continuous Duty
Max. Test Load, Push / Pull
ELECTRICAL CHARACTERISTICS
POWER CLASS
MINIMUM PERFORMANCE AT STANDARD TEST CONDITIONS, STC
1
(POWER TOLERANCE +5 W / −0 W)
Minimum
Power at MPP
1
P
MPP
Short Circuit Current
1
I
SC
Open Circuit Voltage
1
V
OC
Current at MPP I
MPP
Voltage at MPP V
MPP
Efficiency
1
η
MINIMUM PERFORMANCE AT NORMAL OPERATING CONDITIONS, NMOT
2
Minimum
Power at MPP P
MPP
Short Circuit Current I
SC
Open Circuit Voltage V
OC
Current at MPP I
MPP
Voltage at MPP
V
MPP
1
Measurement tolerances P
MPP
± 3 %; I
SC
; V
OC
± 5 % at STC: 1000 W/m
2
, 25 ± 2 °C, AM 1.5 according to IEC 60904-3 •
2
800 W/m², NMOT, spectrum AM 1.5
MECHANICAL SPECIFICATION
Format 1717 mm × 1045 mm × 32 mm (including frame)
Weight 19.9 kg
Front Cover 3.2 mm thermally pre-stressed glass with
anti-reflection technology
Back Cover Composite film
Frame Black anodised aluminium
Cell 6 × 20 monocrystalline Q.ANTUM solar half cells
Junction box 53-101 mm × 32-60 mm × 15-18 mm
Protection class IP67, with bypass diodes
Cable 4 mm² Solar cable; (+) ≥ 1150 mm, (−) ≥ 1150 mm
Connector Stäubli MC4; IP68
TEMPERATURE COEFFICIENTS
Temperature Coefficient of I
SC
Temperature Coefficient of V
OC
Temperature Coefficient of P
MPP
Nominal Module Operating Temperature
QUALIFICATIONS AND CERTIFICATES
Quality Controlled PV - TÜV Rheinland;
IEC 61215:2016; IEC 61730:2016.
This data sheet complies
with DIN EN 50380.
QCPV Certification ongoing.