Product Brochure
Python Steep
Slope Ventilation
System
Weather-Tite™
Rolled Ridge Vent
3-IN-1 FlexFit
Ridge Vent
65 Slant
Back Vent
150 Round Vent
Value drives everything we do. That’s why we developed the Python Steep Slope
Ventilation Division. This comprehensive line of products offers easy installation,
remarkable building ventilation, lower utility costs, extended shingle and roof deck life,
extreme durability, and outstanding warranties. Get more quality, more performance,
and more value ....from Python™
800.800.8590 / MarcoIndustries.com
Specs
Net Free Venting Area: 84 Square Inches of NFVA
Dimensions: Width 15-1/2" x Length 48"
Material: No-break polyproproylene
Codes & Standards: TDI, FL Building Code, CSA
Color: Black
Nails: Bag of 30 - 3" Nails
Roof Pitch: Conforms to any pitch from 2/12 to 12/12
Patents: US Pat No. 7,662,037, US Pat No.
9,175,480, US Pat No. D694,394, Canada Pat No.
2,776,653
Pack Unit of Measurement: 10 per carton
Shingle Cap Sizes: Converst from a standard 12" to
10" or 9" ridge vent
Construction Detail: Closed external baffles with self
closing end caps
Installer Detail: Shingle nail lines for easy installation
Nail Holes: Reinforced to prevent deformation and
crushing
Approvals: FBC FL38704, TDI RV-125
Easy Install
1. Using a chalk line, mark 1" on both sides of the ridge
(1" beyond ridge pole) as a guide for cutting a slot in the
decking.
2. Cut a slot in the roof ridge using a circular saw with
the blade set at a depth to cut through the roof decking
only - avoid cutting trusses and rafters.
3. Center the Python™ 3-IN-1 FlexFit™ Ridge Vent
over the slot that has been cut in the ridge, ensuring
that the RIDGE VENT support pegs sit flat on the roof.
To ensure proper alignment along the ridge, run a chalk
line down both sides of the ridge.
4. Using roofing nails provided, install the vent starting
from the outer edge moving inward. Properly secure by
using the 12" nail holes.
5. As you install more pieces of the RIDGE VENT,
ensure that each piece is joined together using the
male/female connectors.
6. Cut the final piece to a length long enough so that
it is flush with the edge of the roof. Ensure that the
self-closed end cap is facing out to prevent weather
infiltration. (Interlocking feature will not be used on the
final piece.)
7. Install the cap shingles using the nails provided in
the “shingle nail line” area for cap shingle installation as
indicated on the Python™ 3-IN-1 FlexFit™ Ridge Vent.
Visit MarcoIndustries.com for 10" and 9" Cap Shingle
Installation.
See our installation instructions online at MarcoIndustries.com