E-BOX Series User Manual

Pytes E-BOX SERIES LFP Battery User Manual
18
1. The host Link Port 0 must be kept free;
2. The end slave Link Port 1 must be kept free;
Note: The system may not be able to communicate if not
followed the instruction.
Table 5-3 LED indications
Battery
status
Protectio
n / Alarm
/ Normal
RUN
ALM
Capacity LED
Descriptions
Shut down
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
All off
Power-on
Normal
ON
ON
ON
ON
ON
ON
ON
ON
All light on one second at
same time.
Standby
Normal
Blink 1
OFF
OFF
OFF
OFF
OFF
OFF
OFF
Indication standby
Alarm
OFF
Blink 3
OFF
OFF
OFF
OFF
OFF
OFF
Battery low voltage
Charging
Normal
Light
OFF
Base on capacity
Alarm
Light
Blink 3
Protection
OFF
Light
OFF
OFF
OFF
OFF
OFF
OFF
Stop charging, protect start
Discharge
Normal
Blink 3
OFF
Base on capacity
Alarm
Blink 3
Blink 3
Protection
OFF
Light
OFF
OFF
OFF
OFF
OFF
OFF
Stop discharge, protect start
Note: The blinking descriptions, Blink 10.25on/3.75offBlink 20.5s
on /0.5s offBlink 30.5s on /1.5s off.
---End of installation---