Installation manual
PCX 256 PROGRAMMING MANUAL
Page: 60 RINS868-6
key. ARC Details will be displayed. Repeat
the above for any other ARC stations you are
using. Press the key. ‘Program Digi/SMS
Calls?’ will be displayed, press the key.
Program Digi Channels
Press the key to check that the Digi
Channels are what the ARC are looking for.
The first Digi Channel will be shown, once you
have checked this is correct, press the key
to move to the next.
To change this channel please see page 38 for
the output types. All default values are shown on
page 58. Once you have completed all the Digi
Channels, ‘Program Digi Channels will be
displayed’. Press the key.
‘Program SMS Details’ will be displayed and
Press the key.
3 Way Calling
Enter : for No (Default)
Enter : for Yes
Press the key. You will be returned to the
Engineer Menu.
5.23.3 Programming Contact ID, SIA and SMS
The Contact ID, SIA and SMS signalling protocols can also be used. However the programming
differs from Fast Format, here you have to select fixed content types (as opposed to programmable
outputs) you would like to be sent to the ARC. The table below shows all the content types.
Content Types
01 Arm All arm events (by area/level & user name)
02 Disarm All disarm events (by area/level & user name)
03 Special Disarm Disarm events initiated by codes 15 to 20 only
04 Arm Fail Attempt to arm the system failed
05 Alarm All alarm events (by partition, level and type) inc. code guess (excludes
tampers and emergency input types)
06 First alarm First to alarm event (for each input) only
07 Alarm Silenced Any alarm/fault silenced (by partition)
08 Confirmed Sequentially confirmed alarm
09 LoTechFault Telecom Line restore (STU/ATE or DigiModem)
10 HiTechFault Low volts, Battery fault/OK, Fuse failure, RS-485 or Device Failure
11 Tech Info System restart, Over current, Logs cleared
12 Manager Info Code changed / deleted
13 Engineer Info Engineer accessing system, and leaving
14 AccessC Alarm Access Control door forced or left open
15 AccessC Info Access Control tag at Reader