5.18 Engineer Reset Options
The Engineer Reset Options are used so that once an alarm has occurred; the PCX system can
only be reset by an engineer code, anti code or red care reset from the alarm receiving centre.
Option Function
Engineer Restore
of Intruder
Following an intruder alarm, an engineer must reset the system before it can
be used again. Please select ‘UK Intruder’ to enable this, ‘Secure Intruder’
should not be used. This will not interfere with the generation of an
emergency alarm. The default is NO
Engineer Restore
of HU
Following a Hold Up, Input HU or Duress alarm, an engineer must reset the
system before it can be used again. This will not interfere with the generation
of a Fire or Gas (emergency) alarm. The default is NO
Engineer Restore
of Tamper
Following a Tamper alarm, an engineer must reset the system before it can
be used again. This will not interfere with the generation of an emergency
alarm. The default is YES
Engineer Restore
of Soak
In the event of an input with the ‘soak’ attribute triggering whilst the system is
armed, the system must be reset by an engineer before it can be used
again. This will not interfere with the generation of an emergency alarm.
The default is NO
Engineer Restore
of Confirmed
Following a confirmed alarm, an engineer must reset the system before it
can be used again. The default is NO
Engineer Restore
of Faults
If selected, an engineers code will only be able to reset the following faults:
STU/ATE telecom fail, Modem fail, STU/ATE single path fail, Telecom line
fail, Battery disconnect, Batt charge, Batt load, Excessive charge, Battery
critical, Device fail. The default is NO.
Anti Code
Restore
Enables the system to display an anti-code whilst awaiting an Engineer
reset, which can be used to generate a special reset code. The default is
NO.
Visual Keypad Programming Procedure
ENGINEER RESTORE OPTIONS
Engineer Restore Options
Using the and keys, scroll to
‘ENGINEER RESTORE OPTIONS?’ Press the
key
Eng Restore Int
Enter : for No (Default)
Enter : for UK Intruder
Press the key.
Repeat the above options for the restores:
Tamper, Soak, Confirmed, Faults and Anti Code
Restore. (Enter : for No, : for Yes)
You will be returned to the Engineer Menu.