Installation manual
PCX 256 PROGRAMMING MANUAL
RINS868-6 Page: 39
Type Defaults Active Restore
Also once entry time has
started
0020 Exit Starts All
At start of exit time to arm
LAST partition
At code entry to disarm
FIRST partition (i.e. no
longer fully armed)
NOTE: For ‘exit starts’ to be entered in system logs, the site option ‘Confirmed when…’ must
be set to ‘exit start’
0021 Exit Starts Any
When exit time starts to arm
FIRST partition
At code entry to disarm
LAST partition
0022
Final Arm Any
(Open / Close)
ATE 4
DIGI 4
When ANY partition is armed
At code entry to disarm
LAST partition
0023 Strobe Set Fail
Works similar to output 016, but also fires if the set fail
timer expires.
0025
Keyswitch
Disarm
This output turns on for 5 seconds when the system is
disarmed via a keyswitch input (either pulsed or latched
keyswitch)
0031 Entry Live during any exit time
0032 Exit Live during any entry time
0033 Entry/Exit Live during any entry or exit time
0034 Lights
When exit or entry timer
starts
20 seconds after
arm/disarm procedure
completed
0035
Follow Input
See page: 43.
When input triggers
Dependant upon
programming
0036 Shunt Fault See Shunt Inputs - Page: 21
0037
Reset 1 (Viper
Reset)
At code entry to arm After 3 seconds
At code entry to arm When disarmed
0038
Reset 2 (Viper
Arm/Disarm)
Re-triggers whenever an additional partition is armed
0039 PIR Latch 1 PGM 1
When armed (and in Walk
Test)
At alarm, or when
disarmed
0040 PIR Latch 2 This is the inverse polarity to PIR Latch 1
0041 Mains Good Output showing the mains is healthy
0042 Detr Indn Enable
This output activates during walk test and also when a
code is entered to view indications – staying activated for
the time for which the indications are viewed.
0043 Follow Test New output for bell test by activating SAB
0044 Off During Test New output for bell test by activating SAB
0051
Telecom Line
Fault
When Line Fault signalled by
communicator
When fault clears
0052 AC Fail
ATE 8
DIGI 13
After pre-set time without
mains power
On restoration of mains
0053 Battery Faults
When battery disconnected
or load fail detected
At next valid code entry
0054 Low Volts At fault When fault clears
0055
Global Fault 1
(Grade 2)
Activates if input fault occurs
only when system is armed
When all faults cleared
0056
Global Fault 2
(Grade 3)
ATE 9
DIGI 9
Activates if input fault occurs
at any time
When all faults cleared
0057 German Relay Not applicable for UK installations
0058
Guard Code
Used
When ‘guard’ code accepted After 60 seconds