5.15 Change Outputs
The output types below may be programmed to any of the systems PGMs (Programmable
Outputs). Also the function ‘Change Outputs’ is where you install and initialise any Remote Output
Expanders you have installed to the system, this is done under the ‘ROX Module PGMs’. Please
note that the PGMs must be used within their rated capacity.
NOTE: The PGM Outputs CANNOT
be inverted. Only the ATE pins can (See ‘Invert ATE
Outputs in ‘Site Options’ page: 47)
5.15.1 PGM Output Types
Type Defaults Active Restore
0000 Not Used
0001 Fire
ATE 1
DIGI 1
At alarm
When a valid code is
entered
0002 Hold Up Any
At a HU or Duress alarm
(This includes keypad HU)
When a valid code is
entered
0003 Intruder Any
At alarm, while system is
disarmed
At first valid code entry
0004 Final Arm All
When ALL partitions are
armed.
At code entry to disarm
0005
Misoperation Any
(Abort)
When system is silenced
after any ‘intruder’ output is
triggered
After 2 minutes
0006 Confirmed Any
ATE 7
DIGI 7
When further input active in
any partition after ‘intruder’
alarm
At next code entry
0007 Tamper Any
ATE 6
DIGI 12
Any tamper alarm At code entry to silence
0008 Duress
At a Duress alarm (i.e. from
a keypad)
When a valid code is
entered
0009 HU Device Any
ATE 2
DIGI 2
At alarm on a HU input only
(This doesn’t include the
keypad HU)
When a valid code is
entered
0010 Gas At alarm
When a valid code is
entered
0011 Arm Fail
Pre-set time after start of exit
time, if exit procedure is not
complete
At code entry to rearm
0012 Entry Deviation
When deviation from entry
route occurs, during entry
time
At code entry to disarm
0013
Secure Intruder
Any
At alarm, after exit time
started, until disarm
At first valid code entry
0014 Bell Any PGM 5 When alarm live
When alarm silenced or
when siren timer expires
0016 Strobe Any PGM 4 When alarm live
When alarm silenced or
when strobe timer expires
0017 Omit Rearm Any
ATE 5
DIGI 5
At rearm at end of confirm
time if an input in fault is
isolated
When system disarmed
0018 Unconfirmed Any
ATE 3
DIGI 3
Any intruder or Tamper
alarm
At code entry to silence
0019 Can All Arm
If all inputs and technical
faults in system are clear.
If fault exists, and after final
arm