Installation manual
PCX 256 PROGRAMMING MANUAL
RINS868-6 Page: 37
Visual Keypad Programming Procedure
ALARM RESPONSE
Alarm Response
Using the and keys, scroll to
‘ALARM RESPONSE? Press the key
Silent 1
st
Alarm
Enter : for Never (Default)
Enter : for Confirmed
Press the key
Disable Confirm On Entry
Enter : for No (Default)
Enter : for Yes
Leave as NO for use with DD243 clause
6.4.5 or change to YES for use with
DD243 clauses 6.4.3 / 6.4.4. Press the
key.
Inputs to Confirm After Entry
Enter the number of inputs to Confirm after
the Entry. (Leave at 2 to comply with
DD243)
Press the key.
Partition Starts
Enter : for Keypads
Enter : for Internal Sounders
Enter : for Bells Only
Enter : for Digi (Default)
Enter : for Confirm
For defaults see description above
Press the key. Repeat for Partition
Stops and then repeat the above for each
other partition and also for Fire, Gas, HU
and Disarm alarms
You will be returned to the Engineer Menu