Installation manual

PCX 256 PROGRAMMING MANUAL
RINS868-6 Page: 33
5.12.3 User Arm Options
The User Codes can be programmed as the following:
Disarm/Arm: The code will arm and disarm the PCX system (Default)
Disarm Only: The code will only disarm the PCX system once it is fully armed.
Arm Only: The code will only arm the PCX system.
None: The code will not be used to arm and disarm the system.
5.12.4 Flexi Arm
If enabled, the user will be able to select which partitions they can arm/disarm, from those the code
is valid for.
If disabled, the user code will automatically arm in the selected partition(s). This option is
commonly used if a proximity tag has been used on the system. (Default for Duress Codes)
Visual Keypad Programming Procedure
CHANGE CODES
Change Codes
Using the and keys, scroll to ‘CHANGE
CODES? Press the key
5 Digit Pins
Enter : for No
Enter : for Yes (Grade 3) (Default)
Press the key
Change Duress Codes
Press the key to Change the Duress Codes,
or for the next function press the key.
NOTE: User codes can only be changed in
the user manager mode
Duress Codes
Enter the required User Number using the
numeric keys.
Press the key
If a code or tag is already allocated, the display
will show [******]. Enter the new code, or
present a tag to keypad. To erase the existing
code press the F key. Press the key