Installation manual
PCX 256 PROGRAMMING MANUAL
Page: 32 RINS868-6
Visual Keypad Programming Procedure
EXIT MODES
Exit Modes
Using the and keys, scroll to ‘EXIT
MODES? Press the key
Enter : for Timed (Default)
Enter : for Final Door
Enter : for Timed/Final
Enter : for Push To Set
Press the key. Repeat for each partition or
press the key to return to the Engineer
Menu.
5.12 Change Codes (Duress/Guard Only)
All codes may be 4, 5, or 6 digit or proximity tags. Using a 5 or 6 digit code will automatically block
several possible 4 digit codes that clash with it. Please note that the PCX System will only comply
with Grade 3 if you have “5 digit codes” enabled (this is enabled at default). NOTES: Only Duress
or Guard codes can be changed by the Engineer, Normal user codes can only be changed
in The Manager Mode. The Master User and Engineer Codes cannot be deleted.
5.12.1 Code Types and Numbers.
PCX System User/Manager Codes Duress/Guard Codes
PCX 256 500 20
5.12.2 User Types
User Type Functions Operation
User
Default: 1234
Arm and Disarm System. Also for Access Control and
Sub Partition Control functions
Programmed by
Manager only.
Manager
Arm and Disarm System
Also access to Manager menu functions
Programmed by
Manager only.
Master Manager
Default: 5678
Arm and Disarm System.
Also access to Manager menu functions
Programmed by
Manager or Engineer.
Engineer
Default: 9999
Access to all engineering functions; also arm/disarm
system for test purposes.
Programmed by
Engineer.
Duress
Disarm system, generating silent ‘Duress’ or ‘Hold Up’
signal. NOTE: ACPO policy prevents use of duress codes
to police all purposes.
Programmed by
Engineer.
Guard
Disarm system, but only after an alarm has been
active for a minimum time (programmable). Also arm
system. An output type is available to signal whenever
this code is used.
Programmed by
Engineer.