Number & Type Operation
Communicator: ‘Tamper’ signal
When armed: Audible Response: Full (differentiated)
Communicator: ‘Tamper’ and ‘Unconfirmed’ signals
06 Immediate
Active when armed. Audible Response: Full
Communicator: ‘Intruder’ and ‘Unconfirmed’ signal
07
Entry/Exit
(EE)
Active when armed – initiates entry timer if system not disarmed before
entry time expires: Audible Response: Full. Communicator: ‘Intruder’ signal
08 Access (A)
Active when armed, except during entry time. (Acts as an immediate
input if an entry/exit input hasn’t been activated beforehand)
Audible Response: Full. Communicator: ‘Intruder’ and ‘Unconfirmed’ signal
09 A (Part EE)
(For use with part arms). When fully armed, it acts as an Access input as
above, when part armed; it acts as an Entry/Exit input.
10 EE (Part A)
(For use with part arms). When fully armed, it acts as an Entry/Exit input
as above, when part armed; it acts as an Access input.
11
PTS
(Push to set)
Active during exit time to complete arming procedure
No audible or communicator response.
Note: May be used to act as ‘doorbell’ by use of ‘chime’ attribute.
12 Switcher
Active at all times. No audible or communicator response
Triggers associated output or switches other equipment
13 24 Hour
When armed: Audible Response: Full. Communicator: ‘Intruder’ and
‘Unconfirmed’ signals When disarmed: Audible Response:
Programmable. Communicator: ‘Day Alarm’ signal
15
Sub Part
Control
Input is allocated by system software and cannot be reprogrammed to a
different type, though relevant attributes may be adjusted.
16 Fault
Active when armed or disarmed. Audible Response: Graduated internal
Triggers ‘Global Fault 1’ output if the system is armed.
Triggers ‘Global Fault 2’ output if the system is armed or disarmed.
17
Closure
Supervision
Active during arming procedure. No audible or communicator response
Prevents system being armed whilst active
18 Shunt Input
Active at all times. No audible or communicator response
Accepts input from keyswitch (or equivalent) to shunt the inputs assigned
to it. Associated outputs are available. After 10 seconds the detectors in
the shunt list will be active. See page: 21
19 Disarm Input
Active when armed. Accepts input from keyswitch (or equivalent) to
disarm the arm level assigned to it.
20
Keyswitch
Latched
Accepts input from keyswitch (or equivalent) to arm/disarm the arm modes
assigned to it. Arming includes normal exit time, etc. Requires latching
switch action.
21
Entry Shock
Input
Active when system armed. Works in conjunction with EE input type for
detection of forced entry. See page 18 for details.
22 Input Fail Fail
Active when fail. Will give a line fault alarm, and will signal telecom line
fault on expiry of line fault timer. Works in conjunction with CCTV input
23
Keyswitch
Pulsed
Accepts input from keyswitch to arm/disarm the arm modes assigned to it.
Requires momentary action switch to toggle arm/disarm state.
NOTES: ‘Part Arm’ refers to any combination other than all available partitions