Installation manual
PCX 256 PROGRAMMING MANUAL
Page: 10 RINS868-6
4.4 Testing The Keypad
With the system disarmed, press the key for 10 seconds at any keypad. This will cause all the
LEDs on that keypad to illuminate, and the LCD screen to scroll a display testing each pixel. The
keypad will revert to normal display approximately 10 seconds after the key is released.
4.5 Text Programming
Text may be programmed for input names, for the ‘sign-on’ message, and to identify the arm level
being armed / disarmed. Each keypad key is allocated characters as shown below:
To type a word, press the the relevant key the appropriate number of times – e.g. for the letter ‘k’
press the key twice, or for the letter ‘s’ press the key four times.
In addition, the keys are used as follows:
= make the character into a capital
= move cursor left
= clears cursor / adds a space
= moves cursor right
4.6 Accessing the Engineers Menu on Any Keypad
On the PCX 256, it is possible to access the Engineer menu on any keypad. For example, if you
are in the Engineer menu in keypad address 00, the other keypads will display ‘System Busy’, to
access the Engineer menu on any other keypad, press the key.