Specifications

16
FTA : First to Alarm
C+ : Latch Memory
E- : Remote LED Enable
13
RDOC279 issue1
then the new Engineer Code
- gives an audible acceptance tone
then the new Engineer Code again
- gives an audible acceptance tone
If an incorrect key is entered an error tone will be given and the function ended.
9.10 Changing Event Log Reset Status
Should your customer request the ability to clear the memory log then:
Enter
Selecting this function will change the reset status from Engineer only, to Master
and Engineer reset and back again.
This facility is factory set to Engineer reset only.
9.11 Exiting Engineer Mode
Enter
then
Engineer Code
10 USING THE PARAGON SUPER AFTER
PROGRAMMING
10.1 LIMITED USER FACILITIES
10.1.1 Full Setting the panel
Enter either of the following:
Limited User Code (Factory set to 5 6 7 8)
By using this method, maximum volume will be heard.
or
By using this method, volume from extension speakers will be determined by
volume pot.
10.1.2 Part setting the panel
Part set 1 (eg downstairs only armed):
or
Volume from extension speakers will be determined by volume pot. i.e. Reduced volume.
Part set 2 (eg upstairs only armed):
Enter or
Volume from extension speakers will be determined by volume pot. i.e Reduced volume.
Part set 3 (eg whole house armed except garage):
Wiring for normally open contacts.
Wiring to PIRs
NOTE: C+, E- and FTA connections are all optional. FTA connects to all other PIRs in the
same alarm zone. FTA should NOT be connected to the control panel.
Latch Memory (C+)
This feature is very useful when more than one detector has to be wired to a particular
zone as it will show which detectors triggered if an alarm was generated. If there has
been an alarm and latch memory was used then when the panel is reset an LED
indication will be given at the relevant detector(s). Resetting of latch memory requires
the panel to be set again for not less than 5 seconds, and then unset.
Any unused zones should NOT be left open circuit
8.6 POWERING UP YOUR PANEL /RKP
a. Insert the battery and secure it with the cable tie provided.
b. Connect the battery. An alarm will now occur.
Replace the front cover and enter the Master User code:
(Factory Set 1234)
The audible alarm will now stop, the supply Day and fault LEDs will illuminate.
c. Switch on the mains supply. The fault LED will go out. Now proceed to the "9.
Programming" section