Operating instructions
Installing Your Insert Pellet Stove 
VENTING INTO AN EXISTING CHIMNEY 
53 
-RAIN 
CAP 
f* 
INSERT STOVE VENTED INTO 
EXISTING CHIMNEY 
andlor pipe 
support 
The Quest insert may be installed in a masonry 
or factory built fireplace as shown below. When 
I 
installing into the existing chimney, the exhaust 
venting system should be extended to the top of 
the chimney as shown below. However. 
If 
the 
vent pipe is not extended to the top of the 
1 
chimney, it must extend a minimum of 
18 
I 
1/ 
, 
j 
, 
inches ahove the chimney damper. 
If the 
optional horizontal exhaust duct is used, a mini- 
mum of 10 ft. of 
3 
inch vent pipe must be used. 
Ensure that the end of any flex pipe used in this 
, 
. 
type of installation is not blocked, when termi- 
I!; 
I 
!I: 
nated inside the existing flue. 
Note: Any instal- 
i 
: 
I 
lation that does not run all the way to the top 
11 
of the chimney is not recommended. 
;: 
I 
1 
I 
We also recommend that the fireplace cavity be 
thoroughly cleaned and sealed with latex paint or 
masonry sealer. The paint will seal in old soot 
and creosote and help prevent fine dust from 
being pulled into the stove's convection fan and 
blown into the house. 
IMPORTANT 
NOTE: 
Make sure the chimney 
and 
fqlace 
are 
clean 
and 
free 
of soot and ashes 
EEEQ3E 
installation 
begins. Failure 
to 
do so 
may result in the transfer 
i 
of soot into the mom. 