Operating instructions
Mobile Home Installa tion 
. 
p*. 
IN ADDITION TO THE STANDARD 
INSTALLATION INSTRUCTIONS, THE 
FOLLOWING INSTRUCTIONS MAY  BE 
REQUIRED 
BY 
LOCAL, STATE  OR FEDERAL 
BUILDING CODES: 
0 
Stove must be permanently bolted to the floor. 
Stove must have 
a 
permanent outside a 
Stove must be permanently electrically 
chassis of the home. 
The 
location selected 
stove must be dedicated for this purpose. 
Refer to page 
17 
for list of commonly used vent components. 
0 
NOTE: THE GROUNDING OF THIS PRODUCT, AT  INSTALLATION, 
MUST COMPLY 
WITH NFPA-70 STANDARDS,  CSA  C22.1  IN CANADA, 
AS  WELL  AS  ANY LOCAL CODES. 
WARNING: 
DO NOT INSTALL IN A SPACE  USED AS  A BEDROOM. 
I  I 
THE STRUCTURAL INTEGRITY OF THE MANUFACTURED 
HOME FLOOR, WALL  AND 
CEILING/ROOF 
MUST BE  MAINTAINED. 
MOBILE HOME EXHAUST VENT 
PIPE 
INSTALLATION GUIDELINES 
Use only listed type 
"L" 
pellet vent pipe. Pipe 
should extend at least 
3 
feet above the part of the 
roof through which 
it 
passes. The top of the pipe 
should be at least 
2 
feet above the highest required 
elevation of any part of the mobile home within 
10 
feet of the pipe. 
If exhaust vent exits the mobile home at a location 
other than the roof, and exits at a point 
7 
feet or 
less above the ground level on which the mobile 
home 
is 
position a guard or method of enclosing 
the pipe shall be provided at the point of exit for a 
height of up to 
7 
feet. The openings, if any,  in this 
guard shall not allow a 
314" 
rod to pass through. 
A 
112'' 
rod could pass through but should not be able 
to touch the pipe when inserted through the 
opening a distance of 
4 
inches. 
Sfeel Chassis of' 
~ledrical Gound  Noncombustible 
Mobile Home  to Chassis 
floor Protedion 
23 