Operating instructions
Installing Your Freestanding Pellet Stove 
P 
STANDARD HORIZONTAL EXHAUST INSTALLATION 
1. 
Locate the proper position for the listed type 
"L" 
wall thimble.  Avoid cutting wall studs when installing 
your pipe.  Use a saber saw or key hole saw to cut the proper diameter hole through the wall to accommo- 
date the wall thimble. Use extreme caution to avoid cutting into power lines within the wall of the home. 
The hole size will depend on the brand of pellet vent that you are using. Install the wall thimble 
in the hole. 
ALL  INTERLOCKING PIPE  CONNECTIONS WITHIN THE ROOM MUST BE  SEALED  WITH RTVAND 
SECURED 
WITH A MINIMUM OF 
3 
FASTENERS PER  CONNECTION. 
2. 
Position the stove approximately 
12" 
(.3m) from the wall on the floor pad. Push listed type 
"L" 
pipe 
through wall thimble. Squeeze a bead of high temperature silicone 
(RTV) sealer around the end of the 
machined portion of the 3" 
(76mm) pipe connector on the back of the stove. Firmly push on a 
section of listed type 
"L" 
pipe until inner pipe liner pushes into the bead of RTV sealer. 
3. 
Push the stove (with pipe attached) towards wall. Pipe will go through the wall thimble.  Do not position 
the back of the stove closer than 
1" 
(25mrn) from the wall. 
Note: 
Greater back clearance will improve the serviceability of the stove. 
4. 
Install listed type 
"L" 
45 degree elbow with rodent screen or cap (optional) on outside end of pipe. The 
rodent screen should be no less than 
112" (13mm) mesh and may clog with soot and ash if left unattended 
during the burn season. 
NOTE: 
The end of the exhaust pipe must extend a minimum 
of 
72" 
(.3m)  from the outside of the building. 
5. 
If the installation includes a source of outside combustion air; cut a separate hole through the wall for 
the fresh air tube. This tube should be 
1-5/8" (42mm) [min.] diameter, steel only. Connect outside air pipe 
to air inlet on stove. This tube must be terminated with a 
90 
degree elbow or hood. 
NOTE: AIR MAY ALSO BE  DRAWN FROM A  VENTED CRAWL SPACE  UNDER THE HOME. ALL JOINTS 
FOR CONNECTOR 
PIPE SHALL BE  RFOUIRED TO BE  FASTENED WITH AT LEAST  THREE SCREWS. IF 
VENTED HORIZONTALLY, JOINTS 
SHALL 
BE  MADE CASTICHT IN A MANNER AS SPECIFIED ABOVE. 
INSTALL  VENT AT CLEARANCES SPECIFIED BY  THE VENT MANUFACTURER. 
Straight 
"1-vent" 
Thimble 
& 
Fresh 
Air Pipe 