Operating instructions
Operating 
instructions 
p 
Manual Lighting Procedure: 
If 
Priming 
Is 
Required 
1. 
Fill the hopper with recommended pellet fuel and plug the stove into the wall outlet. 
2. 
Press the Start switch on the control panel. This will activate both blowers. Press the Auger 
ON/Off 
switch on the control panel. This will activate the auger motor. Next, press the heat output switch to position 
#5 
(maximum feed rate). 
3. 
Look through the combustion chamber door and when you see the first pellets dropping into the grate the 
auger 
is 
then fully primed. 
It 
will take 
10 
to 
15 
minutes to prime the auger. 
4. 
Once the auger is primed, unplug the stove to turn off the blowers and auger for 
a 
minimum of 30 seconds. 
You need only do this when priming the auger. Once the stove 
is 
shut down,  plug 
it 
into the wall outlet again. 
Manual Starting Steps 
1. 
Place a recommended fire starter (see your dealer for appropriate fire starter) in the burn grate and put a 
handful of pellets on top of the starter. 
DO NOT USE  FLAMMABLE LIQUIDS TO START  YOUR  STOVE. 
2. 
Light the fire starter in the grate with a match and close the door. 
3. 
After approximately 10 seconds, press the 
START  SWITCH. 
You  will notice that the fire will become active 
and there will be air coming from the heat exchanger tubes. 
4. 
After the pellets in the grate are burning sufficiently (red hot coals),  press the Auger 
ON/OFF 
switch: this will 
activate the auger motor, and pellets will begin to feed into the burn grate.  Your blower motors will continue to 
operate. 
5. 
After the pellets are burning well,  press the 
HEAT  OUTPUT 
selector to the desired setting. Combustion 
air and the pellet fuel feed rate will adjust automatically as the 
HEAT  OUTPUT 
selector 
is 
pressed. The flame 
should be bright 
yeflow in color and there should be no evidence of soot formation at the top of the flame. 
Press the Blower Speed switch to increase or decrease the desired amount of convection air from your stove. 
,,.. 
If operating your stove with a wall thermostat, adjust the heat output selector switch to the desired demand 
mode 
(#2 
through #5  on the heat output selector switch). 
Lighting Stove  With Optional Fastfirem Self-Igniter: 
1. 
Fill 
the hopper with recommended pellet fuel and plug stove into wall outlet. 
2. 
Push the 
Start 
button on the control board to activate the igniter. 
3. 
Press the Auger 
ON/OFF 
Switch 
to the 
"ON" 
position. 
4. 
Pellets will start feeding into the grate and should begin to ignite within three to seven minutes. The self- 
igniter will automatically shut-off after 15 minutes. 
5. 
If 
the auger system 
is 
not primed with pellets, as  in a first time starr-up orwhen the stove has completely run 
out of fuel, 
it 
may take a few extra minutes to start. In these circumstances if the stove does not start after the 
15 minute ignition cycle, unplug stove,  plug back in and press start button. 
6. 
Air 
is 
drawn from the convection air system and 
is 
blown across the igniter element to produce a flow of 
super heated air. This stream of air 
is 
directed through a hole in the back of the burn grate. 
Tip: 
set the blower spew' (convection air) selector to a higher setting for better start-up. 
7. 
After the pellets are burning well,  press the 
HEAT  OUTPUT 
selector to the desired setting. Combustion air 
and the pellet fuel feed rate will adjust automatically as  the 
HEAT  OUTPUT 
selector switch 
is 
pressed. The 
flame should be bright yellow in color and there should be no evidence of soot formation at the top of the 
flame. Press the Blower Speed switch to increase or decrease the desired amount of convection air from your 
stove. If operating your stove with a wall thermostat, adjust the heat output selector switch to the desired 
demand mode 
(#2 
through #5 on the heat output selector switch). 
Turning 
Off 
Your Whitfield Pellet Stove: 
Press the Auger 
On/W 
Switch 
to turn the fuel feed off. Pellets will stop feeding and the red light will stop 
blinking. Both blowers will continue to operate. The blowers will automatically turn off after 30 to 45 minutes. 
The low temperature switch will also shut the stove down safely if it runs out of fuel. 
/F 