operation manual
EN
46
Operating Manual: PX-1 - Smoke Alarm Device Operating Manual: PX-1 - Smoke Alarm Device
EN
47
• Easy to maintain and removable ac-
cording to EN 14604:2005/AC:2008
• or maintenance-unfriendly but
theft-proof according to
EN 14604:2005/AC:2008
and vfdb 14/01 (Q)
Adhesive mounting according to
EN 14604:2005/AC:2008
When performing this type of installation,
proceed as follows:
(1) Remove magnetic carrier from the device.
(Remove the splint from the activation
button only after that)
f To do this, tilt the magnetic carrier.
(2) Remove the protective lm from the
adhesive pad on the magnetic carrier.
(3) Press rmly magnetic carrier for about
10 seconds at the mounting position.
(4) Taking the device into operation.
f Observe chapter 6 “Putting into
operation“ on page 50.
(5) Put the device on the magnetic
carrier.
5 The device is mounted on the
magnetic carrier.
The ultimate strength of the adhe-
sive bond is achieved after about
72 hours.
Adhesive mounting ac-
cording to EN 14604:2005/
AC:2008 and vfdb 14/01 (Q)
To establish a permanent connection be-
tween the device and magnetic carrier
according to vfdb 14/01 (Q), you can ad-
ditionally mount the device with the sup-
plied adhesive lm on the magnetic carrier.
5 Installation
The device is held by a magnetic carrier
at the installation location. The magnetic
carrier can be mounted by gluing or drill-
ing. It is imperative to observe the instruc-
tions in this manual and the general safety
instructions in order to prevent injuries
caused by incorrect installation.
CAUTION
Possible property damage!
Using other fastening material (not
enclosed) or wrong conditions at the
installation location can cause the
device to fall down.
f Use only the supplied mounting material
(adhesive pad or screws /dowels).
f Ensure that the mounting location is
strong enough, solid, dry, free from
grease, dust and loose paint etc.
f Note that the magnetic carrier
magnetically attracts only from one side.
5.1 Adhesive mounting
The magnetic carrier can be mounted us-
ing adhesive assembly as follows:
4.4 Rooms with a platform or gallery
0,5
1/2
0,50,5
>16 m² / >2 m
1/2
Fig. 18 Rooms with a platform or gallery
Allowed
Not allowed
Note the following for rooms with plat-
forms or galleries (area greater than
16 m
2
, at least 2 m long and wide):
f Mount additional device under the
platform / gallery.