operation manual

22
REPLACING OVEN LAMP
WARNING: To avoid electric shock, ensure that the appliance circuit is
open before changing the lamp. (having circuit open means power is off)
First disconnect the power of appliance and ensure that appliance is cold.
Remove the glass protection by turning as indicated in the gure on
the left side. If you have difculty in turning, then using plastic gloves
will help you in turning.
Then remove the lamp by turning, install the new lamp with same
specications.
Reinstall glass protection, plug the power cable of appliance into electrical
socket and complete replacement. Now you can use your oven.
Type G9 Lamp Assembly: Type E14 Lamp Assembly:
CLEANING OVEN GLASS
Lift by pressing on plastic latches on left and right side as shown in
gure 19 and pulling the prole toward yourself as in gure 20. Glass
is released after prole is removed as shown in gure 21. Remove the
released glass by pulling toward yourself carefully. Outer glass is xed
to oven door prole. You can perform glass cleaning easily after glasses
are released. You can mount glasses back by performing the operations
reversely after cleaning and maintenance are completed. Ensure that
prole is seated properly in place.
220-240 V, AC
15-25 W
Figure 17
220-240 V, AC
15 W
Figure 18
Figure 19 Figure 20 Figure 21