User manual
33
TIME & ATTENDANCE SYSTEM
If the DB9 does not fit into a port on the computer, you will need a USB to RS232 adapter
to connect the DB9 to your computer. You can purchase this adapter through Pyramid,
P/N 41685.
STEP II: Test that Windows, COM Port and DB9 are working properly.
• If the hardware is setup correctly, you will need to connect the loop-back plug
included in the shipment to the DB9 that is plugged into your computer.
• Click the Reconnect Button on your screen.
• If the loop back plug is found, it indicates that Windows, the COM Port and
the adapter are working properly.
IIa: Test that the Cable is working properly.
• Unplug the white Cat5 cable from the TimeTrax EZ unit and from the back of the PC.
• Plug them both back in, in the reverse order.
• If this still does not work, replace the white cable with another Ethernet or Cat5
cable.
IIb: If the LCD displays time and date, test the Time Clock.
• First, try unplugging the unit and letting it sit for a few minutes, then plug it back
into the wall socket.
• If it is still not connecting correctly, you will need to reset the clock.
NOTE: Resetting the time clock erases all stored punches. To reset the clock, unplug the unit and
hold down the 0 key while plugging it back in. If it does not connect at this point, the clock needs
to be replaced.
Step III: Loop Back Plug Not Found
• If the loop back plug is not found, try connecting a USB to RS232 adapter
(Pyramid P/N 41685) into the PC and then connecting the DB9 to the USB adapter.
• If this still does not work, it may be necessary to contact your computer support
personnel.
Restoring Database From a Crashed Hard Drive
• Reload your TimeTrax EZ Software as shown in the Installing the Software section of this
manual. Note: Please make sure that you are installing the same version that you are currently
running.
• If you have AUTOMATIC BACKUP activated, go to CONFIGURE TAB on the VERTICAL
ICON BAR and Click on AUTOMATIC BACKUP.