User manual
Configuration 3-16
© 2011 Pyramid Solutions Inc. Publication PUB-AB7603-014
Note: The BridgeWay will automatically reset after the DeviceNet configuration
is downloaded from BWConfig.
Setting the DeviceNet Configuration with Node Commissioning Tools
The DeviceNet network configuration may be set using DeviceNet node commis-
sioning tool like RSNetworx or NetTool-DN-D. The parameters discussed above
must be set through the parameter editing function of these tools. See “DeviceNet
Network Configuration” on page 4-1 for details on setting the DeviceNet network
configuration using these tools.
EDS File
Each device on a DeviceNet network has an associated EDS file containing all
necessary information about the device. This file is used by the network configu-
ration tools, such as RSNetWorx or NetTool-DN-D, during configuration of the
network.
The latest version of the EDS file for the BridgeWay can be downloaded from
Pyramid Solution’s web site, or received by contacting Pyramid Solutions.
Input Data Safe
State
Define the safe state for the DeviceNet input
data.
The safe state determines what will happen to
the data in the input table associated with a
DeviceNet slave when the connection to that
slaves times out. Setting the safe state to
“Retain Last State” will cause the slave’s data
to freeze at the last value received from the
slave. Setting the value to “Zero Data” will
cause all input data associated with the slave
to be set to zero.
Retain Last
State
or
Zero Data
Parameter Description Allowable
Range
Table 3-2 DeviceNet Network Configuration Parameters