User manual
Chapter 10 Status and Diagnostics 10-1
© 2004 Pyramid Solutions Inc.
Publication PUB-AB7603-008
Status and Diagnostics
BridgeWay LEDs
There is a group of LED indicators on the front of the BridgeWay that is used to
annunciate the current status of the module and the network interfaces. The layout
of the LEDs is shown in Figure 10-1.
BridgeWay Status LED
Major unrecoverable faults are indicated by a series of green and red flashes. If
the BridgeWay Status LED is flashing red and green for an extended period of
time, count the number of red and green flashes and call technical support.
Figure 10-1 BridgeWay LEDs
State Summary Description
Flashing Green Idle Module is in Idle mode.
Solid Green Run Module is in Run mode.
Solid Orange Hardware
Initialization
The LED will be in this state immedi-
ately after power is applied.
Flashing Red/Green Error A major, unrecoverable fault has been
detected.
Red, Green, Orange
Alternate Flashing
Self Test A self test of the module is in progress.
Table 10-1 BridgeWay Status LED States
BridgeWay Status
Module
Network
Module
Activity
Network
Ethernet
DeviceNet
Status
Status
Status
Status
Link