Instruction Manual

5. Setup Flow Chart
6. Main Features
Designed with independentdual outlets;
Dual Relays, able to control both Heating and Cooling
devices at the same time, or control separately;
Dual Waterproof Sensors, turn devices on and off at
desired temperatures, very easy and flexible to use;
Celsius or Fahrenheit Read-out;
Dual LED Display, read temperature from 2 sensors;
High and Low Temperature Alarm;
Temperature Difference Alarm;
Power-on Delay, protect output devices from excessive
on/off toggling;
Temperature Calibration;
Settings are retained even when power off.
7.Specification
Temperature Range
-40~99°C / -40~210°F
Temperature Resolution
0.1 °C / 0.1°F
Temperature Accuracy
±1°C / ±1°F
Controller Dimension
210x55x40 mm
Input Power
85~250VAC, 50/60Hz
Output Power
85~250VAC, MAX 10A/16A
Buzzer Alarm
High and Low
Temperature,
Temperature Difference
Sensor Cable
NTC Sensorx2, 2m/6.56ft
Input Power Cord
1.35m / 4.5ft
8. MENU Instruction
Menu
Code
Function
Setting
Range
Default
CF
Centigrade/Fahrenheit
C / F
C
1on
Outlet 1 ON
Temperature
-40°C~99°C /
-40°F~210°F
20°C/
68°F
1oF
Outlet 1 OFF
Temperature
-40°C~99°C /
-40°F~210°F
30°C/
86°F
2on
Outlet 2 ON
Temperature
-40°C~99°C /
-40°F~210°F
25°C/
77°F
2oF
Oultet 2 OFF
Temperature
-40°C~99°C /
-40°F~210°F
35°C/
95°F
AL
Alarm Low
Temperature
-40°C~99°C/
-40°F~210°F
-40°C/
-40°F
AH
Alarm High
Temperature
-40°C~99°C/
-40°F~210°F
90°C/
194°F
d7
Alarm Temperature
Difference
1°C~99°C/
1°F~210°F
99°C/
210°F
P7
Power-On Delay
0-10mins
0 (min)
C1
Sensor 1 Calibration
-10°C~10°C/
-18°F~18°F
0°C/
0°F
C2
Sensor 2 Calibration
-10°C~10°C/
-18°F~18°F
0°C/
0°F
9. Support and Warranty
Pymeter products are provided Lifetime Warranty and
Technical Support.
Any question/issue, please feel free to contact us any time
on www.pymeter.com or Email support@pymeter.com.
User Manual PDF
LiveChat Support
Temperature Difference Alarm(d7): (Example) if set d7
to 5°C, when temperature difference between sensor 1
and sensor 2 is over 5°C, it will alarm with sound “bi-bi-
biii.
Power-On Delay(P7): (Example) if set P7 to 1 min, outlets
wont turn on until 1 min countdown since last power off.
How to Calibrate Temperature?
Soak the probes fully into the ice-water mixture, the actual
temperature should be 0/32, if the reading
temperature are not, offset(+-) the difference in Setting -
C1/C2, save and exit.
Attention: Don't compare it to common inaccurate
thermometer or temp gun! Please Calibrate with
ice-water mixture (0/32) if necessary!
Remarks: Buzzer will alarm with sound “bi-bi-biii” until the
temperature is back to normal range or any key is pressed;
EEE” is displayed on PV/SV window with “bi-bi-biii” alarm
if sensor is fault.
SET
CF
SET
1on
20°C/6F
SET
1oF
30°C/8F
2on
35°C/9F
2oF
25°C/7F
SET
SET
AL
-4C/-40°F
AH
9C/194°F
SET
d7
9C/210°F
P7
0 (min)
C1
0°C/0°F
C2
0°C/0°F
SET
SET
SET
SET
Working
Normally
SAV
Centigrade or
Fahrenheit Unit
Outlet 1 ON
Temperature
Outlet 1 OFF
Temperature
Oultet 2 ON
Temperature
Outlet 2 OFF
Temperature
Alarm Low
Temperature
Alarm High
Temperature
Alarm
Temperature
Difference
Power-On
Delay
Sensor 1
Calibration
Sensor 2
Calibration
x 3s
PV
SV
Press and hold 3 seconds
Current Temperature
C/F
SET