Tus neeg siv phau ntawv

© Master Instruments Pty Ltd RT12100-Bluetooth-App-Manual_Rev_25/08/22 page 5 of 5
6. Programming of master BMS for Series and Parallel connection.
To supply the correct information to external devices such as Victron
Venus devices, the system parameters need to have the correct
number of batteries in series or parallel.
A 12V System (1S) can be scaled up to 16 in parallel
A 24V system (2S) up to 8 in parallel
A 36V system (3S) up to 5 in parallel
A 48V system (4S) up to 4 in parallel
Press confirm to set the parameters.
7. Heating Function on/o
Activates heater Pad. Heater pads are active to enable low
temperature charging of Lithium batteries.