2.2.1 System Parameter
2.2.1.1 Single group system parameter
Product Type
Force-H2-V2
Cell Technology
Li-iron (LFP)
Battery System Capacity(kWh)
7.10
10.65
14.20
Battery System Voltage(Vdc)
192
288
384
Battery System Capacity(AH)
37Ah
Battery Controller Name
FC0500M-40S-V2
Battery Module Name
FH9637M
Battery Module Quantity(pcs)
2
3
4
Battery Module Capacity(kWh)
3.552
Battery Module Voltage(Vdc)
96
Battery Module Capacity(AH)
37
Battery System Charge Upper
Voltage(Vdc)
216
324
432
Battery System Charge
Current(Amps, Standard)
7.4
Battery System Charge
Current(Amps, Normal)
18.5
Battery System Charge
Current(Amps, Max.@15s)
42
Battery System Discharge Lower
Voltage(Vdc)
174
261
348
Battery System Discharge
Current(Amps, Standard)
7.4
Battery System Discharge
Current(Amps, Normal)
18.5
Battery System Discharge
Current(Amps, Max.@15s)
42
Short circuit rating(Amps)
4000