User Manual
!
When the battery of the watch drops to a low level, the Low Battery Indicator will be ON to remind user.
!
In any Modes, hold all the 4 buttons for more than 5 seconds will reset all the settings of the watch. After
reset, all parameters and pairing of chest belt need to be set again.
!
In Time Mode, press and hold for 5 seconds to go into Power Saving Mode (turning off the LCD).
Timekeeping function is still running under Power Saving Mode. Press any key to resume from this mode.
16.0 Low Battery Indication
17.0 Reset the Watch and Power Saving Mode
16
1) Cause: Dry Skin.
Solution: Apply conductive gel or saliva thoroughly to chest area. (Even water will help if conductive gel is
not available).
2) Cause: Chest belt is not placed firmly over the chest.
Solution: Make sure the Chest belt is placed firmly over the chest by tightening elastic band.
3) Cause: Muscle tremors caused by holding the Chest belt too hard on your chest.
Solution:
This will ensure good and consistent readings even while walking or jogging with arms swung naturally.
4) Cause: Dead skin on chest.
Solution: Usually rubbing your chest with a towel will help.
5)Cause: A thin layer of body grease can insulate the ECG signal-basically prevents the back sensor on
the Chest belt from picking up one's ECG.
Solution: Wipe chest and the contacts on the back of Chest belt with a tissue or soft towel.
6) Cause: Hairy chest.
Solution: Apply conductive gel to chest area.
7)Cause: Irregular heartbeats.
Solution: N/A. It is difficult to consistently pick up a reading for those with irregular heart beats.
Inconsistent response times are expected for those with arrhythmia.
8)Cause: Low Battery.
Solution: It might be due to the battery level of the Chest belt is low. Replace the battery of the Chest belt.
The contacts must make firm contact (NOT too hard) with the user's skin during measurement.
18.0 Potential Causes for NO Heart Rate Reading or Long Response Time
Power Saving ModeReset Display (Full Segment ON)
(5 seconds later)(5 seconds later)