5.5 Mountingoftheuppertting
1. Insertthewhiteplasticinstallationcover(a)intotheframeoftheuppertting.Thecoverisonlysuitablefor
foottrafc(seeFigure4).
2. Adjusttheupperttinginthetankopeninguntiltheedgeoftherimislevelwiththenishedoor.Therim
shouldalsobeparallelwiththewalloroortiles.
3. When installation is complete remove the installation cover and insert the cover with siphon (b) into the
frame.Thiscoverisonlysuitableforfoottrafc.
Heightadjustmentupto130mmispossiblebypushinginorpushingouttheuppertting.Itispossibleto
increase the depth at which the collection tank is installed by the use of one sump extension piece. These
extend the sump by 150 mm.
ATTENTION! A maximum of one sump extension piece may be tted.
(a)
(b)
1065-00
1066-00
Figure 4: Mounting of upper tting Figure 5: Sanisett above-ground lid
5.6 Level control
Theoatswitchesrequiredfor
the twin-unit Sanisett should be
ttedintothecollectiontankatthe
correct level setting.
ATTENTION! Press the oat
switch cable into the plastic
swivel in the holding bracket at
a distance of 15 mm between
the oat switch housing and
swivel. The oat must face
away from the tank wall.
Whenoatswitchesareinstalled,
Robusta pumps should be set to
”Hand” operation.
Theconnectionlinesfortheoat
switches should be connected to
thecontrolpanelbyaqualied
person in accordance with their
designated switching levels A and
B, and the circuit diagram.
*
*
A
B
15 mm
15 mm
X
1064-01
Figure 6: Sanisett oat switch installation