Chapter 5: Configuration
Imager
Ikôn Rugged PDA (Windows CE 5.0) User Manual 197
Min Scan Duration
This parameter defines the minimum amount of time in seconds that the imager will scan 
when the trigger is pressed and held down without successful decode. 
Captures Per HW Trigger
The value assigned to this parameter determines the number of captures the imager device 
will take while the imager's internal hardware trigger is held down. 
Auto Exposure
Setting this parameter to on allows the imager to make automatic gain, integration and illu-
mination adjustments based on ambient light before capturing the bar code. If the 
adjustment is insufficient, further adjustments are made automatically before another image 
is captured.
Fast Converge
Setting this parameter to on speeds the “Auto Exposure” process. It allows the imager to 
rapidly snap a number of bar code capture attempts while finding ideal values for gain, inte-
gration and illumination.
Note: The actual scan duration when the trigger is pressed relies on the value assigned to 
“Captures Per HW Trigger”, below.
Note: This parameter, together with “Min Scan Duration”, determines the actual scan 
duration. When the scan trigger is pressed and held down, the driver starts a timer 
based on the value of “Min Scan Duration” and also sends a command to emulate 
the hardware trigger. When completed, if the time has not yet expired, it will send 
another command to the imager device, forcing the imager to flash again using the 
value assigned to “Captures Per HW Trigger”.
Important: This parameter value should only be changed by qualified Psion Teklogix 
personnel. It should be left at the default value: on.
Note: “Auto Exposure” must be set to on in order for this parameter to function. 
Keep in mind that while this parameter can improve imager performance, “Fast 
Converge” increases battery power consumption.