PDA User Manual
Chapter 5: Configuration
Power Management Properties
Ikôn Rugged PDA (Windows CE 5.0) User Manual 103
data stored on the Ikôn. Once the Ikôn shuts down, it cannot be switched on until a fresh 
battery is installed, or the unit is inserted in a docking station or cradle.
•Slide the Suspend Threshold button to the right to increase the battery capacity 
reserved for backup purposes. Data will be preserved to a maximum of 124 hours.
•Slide the Suspend Threshold button to the left to decrease the power reserved for 
backup purposes; this increases the Ikôn’s operating time—the amount of time the Ikôn 
will operate before shutting down—but reduces the power reserved for backup purposes 
to a minimum of 24 hours. 
Internal super-capacitors will protect the data stored in the Ikôn while the battery is swapped 
for a fully charged one. 
5.5.5.4 Advanced
Allow Suspend With:
This menu allows you to specify whether or not your unit will enter Suspend state while it is 
operating with an active PPP connection, network interface or active TCP/IP connection.
Low Power Warnings
The sliding scale at the bottom of this menu allows you to specify the remaining battery ca-
pacity at which a warning message is displayed on the Ikôn screen, from 0% to 20%.
Important: Once the battery is removed, the super-capacitors will preserve the data 
stored on the Ikôn for approximately 5 minutes. It is critical that you install 
a charged battery before this time elapses.










