User Guide AS/NZS 3497 Licence No. WM 74617 Australian Certification Services NOV2018 Puretec X3 / X4 Inline Undersink Water Filter System For correct operation & installation it is essential to observe these instructions.
What's Inside What's inside Operation................................................................................................................................................ 2 Cartridge Replacement.................................................................................................................... 2 Installation Requirements and Procedure............................................................................ 3 Cartridge Changeout...................................................
Installation When replacing cartridge, ensure you reset the LED reminder light by removing/replacing the battery from the rubber seat. Please refer to page 6 for a detailed diagram. Replacement cartridge code for X3 model : Puretec IL149Q Replacement cartridge code for X4 model : Puretec IL150Q Installation This system comes complete with an installation kit enabling it to be connected to 15 mm (½”) male thread. Installation Requirements 1 15mm (½”) Cold water line - mains only.
Installation Guide 8. Fit tubing into connectors (for quick-connect fittings see Fig 2). Allow slack in the tubing. 9. Restore the water supply and check for leaks. 10. Run the system for at least 5 minutes to remove carbon fines. Water may appear milky, but this is normal and is only tiny air bubbles that will clear after a short period. Cartridge Installation/Changeout 1. Place container under filter in case of drips. 2. Isolate water supply and release water pressure by operating faucet lever.
Assembly FIGURE 1 10 1 3 5 9 6 8 7 FLOW 2 No. 2 4 2 DESCRIPTION 1 Adaptor Ball Valve ½"M x ½"F x ¼"T 6 Tube, Nut and Ferrule 2 Flexible White Tubing 7 Tube Insert 3 Pressure Limiting Multivalve 8 Faucet Lock Nut and Washer 4 Inline Filter Cartridge 9 Black Plastic Washer 5 Mounting Bracket 10 LED Faucet Figure 2 HOW TO USE QUICK CONNECT FITTINGS 1. Cut the tube square and push in to the tube stop.
Faucet Connections Battery Installation LED reminder light Figure 3 Important note: Battery must be replaced when changing cartridges. Faucet Display 1. Remove the black battery seat from the faucet lever handle (see Figure 3). 2. Install battery into the battery seat, positive side up. Battery Seat Escutcheon Positive side up. Circuit Board Battery (CR2032) O-Ring Negative on the PCB.
Performance Data Performance Data Substance Average Influent Concentration Guidelines* Max Effluent Concentration Min Percent Removal Average Effluent Concentration Average Percent Removal <0.1 25% <0.1 >94% NSF Standard 42 Drinking Water Treatment Units Chlorine (9,500 L) 5 - Health 0.6 - Aesthetic 1.8 Test Parameters TDS mg/L 310 Temp deg C 22 Turbidity NTU ND (0.1) pH 7.
Warranty WARRANTY Any claim under this warranty must be made within 3 years of the date of purchase of the product. This product is warrantied to be free of defect of material and workmanship for 3 years from date of purchase. Warranty is 1 year parts and labour plus 2 years parts only. Excludes cartridges. To make a claim under the warranty, take the product and proof of purchase to place where you purchased the product, and they will lodge a Warranty Request with Puretec.