User Guide WMTS 105 Certificate No. 23291 Pro-Switch OCT2022 Sparq S5 Sparkling, Chilled & Ambient Water Filter System For correct operation & installation, it is essential to observe these instructions.
What's Inside What's Inside Puretec Customer Service ...........................................................................................................................3 Installation Record ...........................................................................................................................................3 Before Installation.............................................................................................................................................
Introduction Puretec Customer Service Thank you for purchasing a Puretec Sparq S5 Drinking Water Appliance. The Sparq S5 is a proven performer manufactured from only quality materials and components. It will give years of reliability and trouble-free operation if maintained properly. Caution: Do not use with water that is microbiologically unsafe or without adequate disinfection before or after the system. The Puretec Sparq S5 is designed for use with metropolitan supply water applications only.
Before Installation Before Installation VERY IMPORTANT! Carefully read through this instruction booklet and check that all requirements can be met. Failure to meet requirements may result in voided warranty. • Check the mains water pressure is between 138 - 500 kPa. Note: Where maximum line pressure exceeds 500 kPa, the supplied multivalve must be installed to comply with Australian Plumbing Standards. (Ref. AS/NZS 3500.1:2021, Clause 3.3.
Parts Included Parts Included Unpack the equipment. Ensure all parts are present and have not been damaged in transport.
System Identification Figure 1 - Dimensions 290 mm 93 mm 230 mm min. 150 mm air gap 110 mm 405 mm 350mm (Coloured) & 345 mm (Chrome) 197 mm A Ø26mm hole is required for faucet (Max. 30mm).
System Identification Figure 2 - CO2 Bottle Pressure Gauge Pressure Regulator CO2Tube (Black) CO2 Bottle TOP VIEW Pressure Gauge Pressure Regulator CO2 Bottle SIDE VIEW Copyright © Puretec Pty Ltd 2022 Puretec Sparq S5 User Guide 7
Ventilation Figure 3 - Clearance Envelope Warm air OUT via buffer pad gap. 550 mm Clearance Envelope 50 mm 50 mm Warm air IN via cabinet floor cutout or kickboard ventilation grille. NOTE: Clearance at the back of the until from the wall needs to be 150 mm.
Ventilation Figure 4 - Buffer Pads & Floor Air Gap Upper cabinet rail sits flush with cabinet door. No air gap. Standard cabinet floor in contact with door. No air gap. Buffer pads installed to create air gap. and allow warm our OUT. A. Cabinet floor cutout to enable cool air IN. Ventilation For air flow cutouts a drill and jigsaw, keyhole or wall board saw will be required.
Ventilation Cutouts HINT: First mark & drill pilot holes in each corner of the required cutout, finishing cutout with a jigsaw, keyhole or wall board saw. To allow the cool air to be drawn into the cabinet, cut out the cabinet floor as shown in Fig. 4 and Fig. 5 (A. Cabinet Floor cutout). Ideally this should be as large as possible along the cabinet for maximum ventilation. Alternatively, a ventilation kit (not included) can be installed by cutting out a hole for a kickboard ventilation grille (see Fig.
System Identification Figure 6 - Exploded Diagram Sparq Faucet Straight Connector Wiring Loom CO2 Tube (Black) Water Outlet (White) Water Inlet (Cold Line) SmartTee™ Tap WATER OUT WATER IN CO2 IN Multivalve (Pressure Limiting Valve) Unit Power Supply Z1 Filter Cartridge & Mounting Bracket Water Inlet Connection (Blue) Note: All cold water lines are 1/4" tube.
How To Operate The Tap How To Operate The Tap When the blue light is on, the tap is in 'Sleep Mode'. Press any button once and the LED light will change from blue to green to indicate that the tap is ready. Press the button again to start dispensing water. Cold Water Cold Water Press and release any button, once the light is green press & hold the cold water button to dispense cold water.
SmartTee™ Figure 5 - SmartTee™ Quick Connect Fitting 1. Turn the quick connect nut on the SmartTee™ anti-clockwise to release the collet. 2. Cut the tube square and push into the tube stop (inside the collet). For metal tube; remove burrs and chamfer tube end to prevent O-ring seal being damaged. 3. The fitting grips before it seals. Ensure the tube is pushed all the way into the tube stop. 4. Once the tube is secured in position, turn the quick connect nut clockwise to secure. Note: Hand tighten only.
Installation Installation VERY IMPORTANT! The following installation sequence must be followed in the correct order and as specified in this user guide by suitably qualified tradespeople. The unit and CO2 Bottle must be installed upright (as depicted within this user guide) In the event of a leak or electrical fault, the unit must be isolated from both power and water. Advice should be sought out by the relevant licenced tradesperson.
Installation 9. Choose the best position for the unit with the required 150 mm clearance for ventilation to the rear and top of the unit and in a suitable place where water spillage will not cause damage. 10. Select a suitable location for the Z1 Ultra Z Filtration System that is close to the unit. Note: Remember to allow access room for changing the filter and a suitable place where water spillage will not cause damage. Location should not be in direct sunlight. 11.
Commissioning 20. Connect the CO2 bottle to the regulator by screwing the regulator clockwise onto the bottle firmly, but taking caution not to overtighten as this may cause the sealing rubber to perish and leak. Use soapy water on the connection between the bottle and regulator to test for leaks. Note: Some CO2 will escape as the valve in the bottle is depressed during connection. 21. Attach one end of the black tube to the regulator (See Fig.
Gas Replacement 3. Turn off the water supply at the inlet (SmartTee™ valve). 4. Purge the soda water line of any air by pressing on the sparkling button on the tap for 30 seconds. Note: To activate water flow, press the button once and the ring light on the top of the tap body will go green, then press and hold the button again for water flow. 5. Turn on the water supply at the inlet (SmartTee™ valve). 6.
Filter Replacement 4. Slowly open the CO2 regulator by turning the black knob clockwise(+) until the gauge reads 3 - 4 Bar but not exceeding 4 Bar. 5. Operate the sparkling button on the tap for 10 - 15 seconds and allow the tank to refill for approximately 1 minute, repeating this process until water carbonation is noticed in the dispensed water. Note: The Bar pressure on the CO2 gauge will fluctuate between 3-5 Bar during this process and normal operation. 6.
Troubleshooting Troubleshooting SYMPTOMS No cold water. POSSIBLE CAUSE POSSIBLE SOLUTION Cold temperature switch is off. Please turn the cold temperature switch on. Refrigerant is low. Call your service provider. Problem with compressor or thermostat. Call your service provider. Ice blockage. Please turn off the power supply and allow 24 hrs for the blockage to melt. No water inside the cold water tank. Please check mains water supply. Filter change due. Replace filter. CO2 bottle is empty.
Warranty WARRANTY Any claim under this warranty must be made within 2 years of the date of purchase of the product. This product is warranted to be free of defect of material and workmanship for 2 years from date of purchase. Puretec is renowned for its quality and after-sales support so if you have any issues please call 1300 140 140 (AU) or 0800 130 140 (NZ). To make a warranty claim, contact us directly or the place of original purchase.
Warranty WARRANTY / AUSTRALIA This warranty is given by Puretec Pty Ltd, ABN 44 164 806 688, 37-43 Brodie Road Lonsdale SA 5160, telephone no. 1300 140 140 and email at sales@puretec.com.au. This warranty is provided in addition to other rights and remedies you have under law: Our goods come with guarantees which cannot be excluded under the Australian Consumer Law. You are entitled to replacement or refund for a major failure and to compensation for other reasonably foreseeable loss or damage.
Installation & Operation Manual Copyright © Puretec Pty Ltd 2022
Copyright © Puretec Pty Ltd 2022 Puretec Sparq S5 User Guide 23