Step 1: Press NEXT and
simultaneously for 5 seconds.
Step 2: Hardness : Set the amount of hardness in grains of hardness
as calcium carbonate per gallon using the
or
buttons. The
default is 13 with value ranges from 1 to 150 in 1 grain increments.
The conversion factor to mg/l or ppm is 17 (divide mg/l or ppm by 17
= grains/gallon).
Step 3: Day Override: When gallon capacity is set to off, sets the
number of days between regeneration. The default is set to 28
days. When gallon capacity is set to AUTO or to a number, sets the
maximum number of days between regeneration. If value set to ‘OFF’
regeneration initiation is based solely on gallons used. If value is set
as a number (allowable range from 1 to 28) a regeneration initiation
will be called for on that day even if sufficient number of gallons
were not used to call for a regeneration. Set Day Override using
or
buttons:
• Number of days between regeneration (1 to 28); or
• ‘OFF’
Press NEXT to go to step 4. Press REGEN to return to previous step.
OTHER SETTINGS
SET TIME OF DAY
The user can also set the time of day. Time of day should only need to
be set aer expended power outages or when daylight savings begins
or ends. If an extended power outage occurs, the time of day will flash
on and off which indicates the time of day should be reset.
Step 1: Press SET CLOCK
Step 2: Current Time (hour): Set the hour of the day using
or
buttons.
Press NEXT to go to step 3.
Step 3: Current Time (minutes) : Set the minutes of the day using
or
buttons. Press NEXT to exit Set Clock.
Press REGEN to return to the previous step.
GENERAL OPERATION
When the system is operating one of two displays will be shown.
Pressing NEXT will alternate between the displays. One of the displays
is always the current time of day. The second display is one of the
following: days remaining or gallons remaining. Days remaining is the
number of days le before the system goes through a regeneration
cycle. Capacity remaining is the number of gallons that will be treated
before the system goes through a regeneration cycle. The user can
scroll between the displays as desired.
If the system has called for a regeneration that will occur at the
present time of regeneration, the words REGEN TODAY will appear on
the display.
When water is being treated (i.e. water is flowing through the system)
the word ‘Soening’ or ‘Filtering’ flashed on the display if a water
meter is installed.
Programming - E3
Programming
SET HARDNESS
1
2
SET
CLOCK
REGEN
NEXT
SET
CLOCK
REGEN
NEXT
SET
HARDNESS
REGEN
DAY
3
SET
CLOCK
REGEN
NEXT
DAY
GAL
REGEN
TODAY
SET
CLOCK
REGEN
NEXT
TIME
SOFTENING
P M
REGEN
TODAY
OR
SET
CLOCK
REGEN
NEXT
REGEN TODAY will
flash if a regen-
eration is expected
‘Tonight’.
SET
CLOCK
REGEN
NEXT
REMAINING
CAPACITY
REMAINING
SOFTENING
SET TIME
PAM
SET
CLOCK
REGEN
NEXT
PAM
SET TIME
1
2 3
SET
CLOCK
REGEN
NEXT
SET
CLOCK
REGEN
NEXT
continued on the next page