User Guide

11 Copyright © Puretec Pty Ltd 2023 SOL-E3 User Guide
Position the Soener on a level surface. The unit must be installed on a surface or
pad that is stable, level and able to support the entire base and wet weight of the
unit.
Installing the Bypass (optional - purchased separately)
Environmental conditions
Operating temperature: 0 - 48°C
Water conditions
Temperature: 0 - 50°C
Pressure: 138 - 862* kPa
* Where line pressure exceeds 500 kPa, an approved pressure
limiting device must be installed to comply with Australian &
New Zealand Plumbing Standards. (Ref. AS/NZS 3500.1:2021,
Clause 3.3.4).
Uninstall the plastic fittings
by turning the knob counter
clockwise.
Connect the bypass assembly followed
by the plastic fittings. Hand tighten the
knobs, do not overtighten.
Refer to page 18 for bypass operation.
4
5
Installation Procedure