User Guide
7 Copyright © Puretec Pty Ltd 2021 Food Service Reverse Osmosis System
Installation
Installation Note: A water filter system/tap, like any product, has a limited life and may
eventually fail. Also sometimes failure happens early due to unforeseen circumstances. To
avoid possible property damage, this product should be regularly examined for leakage and/
or deterioration and replaced when necessary. A drain pan, plumbed to an appropriate drain or
outfitted with a leak detector, should be used in those applications where any leakage could
cause property damage, and/or the water supply should be turned off if no one is present.
INSTALLATION MUST BE COMPLETED BY A LICENCED PLUMBER. FAULTY OPERATION
DUE TO UNQUALIFIED PERSONS WILL RESULT IN VOIDED WARRANTY COVERAGE.
Installation
1. Place the RO system in a cool & dry location, allowing 200mm below the unit for lter
changeouts.
2. Mount the unit to the wall using the pre-cut holes in the bracket.
3. Isolate the water supply and release the pressure.
4. Connect the water supply to the ⅜” Inlet (LEFT side) and the ⅜” Outlet (RIGHT side) to the
machine.
5. Connect the ¼ BLACK tubing to the Drain, DO NOT connect this to the inlet of the machine.
An inline ow restrictor is pre-installed for water supply under 500 mg/L [ppm] TDS. If
your water is above 500 mg/L [ppm] TDS you will need to change the ow restrictor to the
supplied ow restrictor marked “2000”.
Note: If installing a holding tank connect to the Holding Tank Connection, ensure Valve is in
the OFF position.
6. Rotate the Needle Valve in a counterclockwise motion until the valve is in full Bypass mode.
7. Turn on the water supply slowly, until the system has lled with water.
8. Rotate the Needle Valve in a clockwise motion until the valve is in full ltration mode.
9. Flush the RO membrane for 3-5 minutes by opening the shut o valve on the blue ush line
(see illustration on Page 6) and connect this ush line to the closest drain point.
10. Turn on the TDS Meter by pressing the RED Power button on the top left corner. Press on the
OUT button to view the Outlet TDS level.
11. Rotate the Needle Valve in a counterclockwise motion until the desired TDS level has been
reached.
Note: If utilising a holding tank, turn the Valve into the OPEN position and allow 5-10
minutes for the tank to ll. Flush/drain the tank twice in a row to purge the system.
12. Your system is now ready for use.