Multipure ® Multipure Aquaversa and Aquaperform Drinking Water Systems- Countertop Models For Model Nos. MP750SC, MPCT, and MP880SC Owner's Manual Please retain this manual for future reference. Multipure Corporation l P.O. Box 34630 l las Vegas, nV 89133-4630 Phone 702.360.8880 l Toll-Free 800.622.9206 www.multipure.
Multipure Drinking Water Systems Thank you for selecting a Multipure Drinking water system to meet your need for quality drinking water. You have acquired one of the finest drinking water treatment devices available for the reduction of a wide array of contaminants. we are confident that your Multipure system will make a difference in your life. Thank you for your business. Table of Contents I. General Information a. warranty.................................................................................
I.B. Operation and Maintenance Specifications Multipure Drinking water systems have been extensively tested and certified by independent agencies so as to provide you with the highest level of assurance that the device will perform as claimed. Please read this manual carefully before proceeding with the installation. Installation, operation and maintenance requirements are essential to the performance of your Drinking water system.
I.C. Installation Overview & Part Numbers Model MPCT (for countertop use only) Model MP750SC 1 2 1 3 13 Hose Model MP880SC 13 4 3 Diverter Valve 3 2 Diverter Valve 1 11 3 2 13 5 16 4 6 7 6 7 8 12 Part Numbers 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 16.
II. Countertop Installations - Preparing the Housing The Models MP750sC, MPCT, and MP880sC Drinking water systems are designed for use on the countertop adjacent to your sink. Countertop models offer outstanding performance and high-quality features. Designed for convenience, countertop units are easily attached to most faucets without the use of special tools. Multipure’s countertop models include easy-to-use diverters that allow you to switch from filtered to unfiltered water.
III. Connecting the Hose and Diverter Valve to Your Faucet Countertop models sit on the counter next to the sink and are connected with a hose and diverter valve to your existing faucet. 1. The water at your sink should be turned off. 2. remove the aerator or screen from the end of your faucet. 3. attach the Diverter Valve directly to the faucet spout. If the threads of the Diverter Valve don't match the threads of your faucet, use one of the adapters provided with your unit. a.
IV. Connecting your Drinking Water System to Faucet IV.A Connecting Model No. MP750SC spout This stainless steel unit comes with the hose assembly attached to the housing top, and the unit sits on the countertop next to your sink. This model may be converted to below sink use with the purchase of a conversion kit. see section II for instructions on installing the filter cartridge in the housing. To complete the installation and engage the unit: 1.
V. Start-up and Use of Your Countertop Drinking Water System Congratulations, your Drinking water system has been connected to your faucet and you are now ready to start-up the unit, as follows: 1. using a paper towel or cloth, dry off all connections. 2. also, dry off the drinking water unit. 3. ensure that all connections are tight (CauTIOn: DO nOT OVer TIGHTen). 4. Turn on the water. 5. Push the bypass lever of the diverter valve to start the flow of water through the unit. 6.
VI. Filter Life Filter life will vary in proportion to the amount of water used and the level of impurities in the water being processed. Claims of capacity are not applicable to contaminants reduced by mechanical filtration because of broad variations in the quality and quantity of physical matter in your drinking water. Your Multipure filter will clog, protecting you from these contaminants, and your flow rate diminishes. For contaminants reduced by adsorption, filter life/capacity is: Model nos.
VIII. Instructions for Changing Your Filter INSTRUCTIONS - STAINLESS STEEL MODELS 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 16. 17. 18. 19. 20. 21. 22. remove plastic wrapper and instruction wrap. It may be advisable to place a pan beneath the housing before opening it. Confirm that water is off. shut off diverter valve by pushing inward on the stem. Go to Item #7 to continue the instructions for the countertop models. Open drinking water faucet to relieve pressure.
IX. Certification Multipure Drinking Water Systems Product Performance Tested and Certified Multipure Drinking water systems have been tested and certified by nsF International to comply with nsF/ansI standards 42 and 53 for the reduction of specific contaminants being considered as established or potential health hazards.
X. P e r f o r m a n c e D a ta S h e e t Performance Data Sheet Multipure Drinking water systems have been tested and certified under nsF/ansI standard nos. 53 as shown below. The concentration of the indicated substances in water entering the system was reduced to a concentration less than or equal to the permissible limit for water leaving the system, as specified in nsF/ansI 53, Health effects. For Model Nos.
X.
X. Performance Data Sheet (continued) NSF/ANSI 42 - Aesthetic Effects The system has been tested according to nsF/ansI standard 42 for the reduction of the following substances. The concentration of the indicated substances in water entering the system was reduced to a concentration less than or equal to the permissible limit for water leaving the system.
Facts About Arsenic (in compliance with nsF/ansI standard) arsenic (abbreviated as) is a naturally occurring contaminant found in many ground waters. arsenic in water has no color, taste or odor. It must be measured by a lab test. Public water utilities must have their water tested for arsenic. You can get the results from your water utility. If you have your own well, you can have the water tested. The local health department or the state environmental health agency can provide a list of certified labs.
XII. Tr o u b l e s h o o t i n g Maintenance Problems Flushing / disinfecting the unit housing: Multipure recommends that you not allow water to sit in a unit for extended periods of time without it being used. If a unit is left unused for more than 10 days, it may need to be flushed/disinfected before you resume use. To 1. 2. 3. 4. 5. flush a unit that may be contaminated: Confirm that water is turned off to the unit. relieve the water pressure (if below sink unit) by opening the unit faucet.
XIII.
For instructions in Spanish, please turn the manual over. Be sure to replace your filter at least once a year, or sooner if needed. Date of Installation:________________________________________ Fecha de Instalación Unit Model Number:_______________________________________ Tipo de Unidad Filter Type:______________________________________________ Tipo de Filtro Dates of Filter Change / Fechas de Cambio del Filtro To order a Replacement Filter Call 800.622.9208 or www.multipure.com/rf.