Owner`s manual

PureLink by Dtrovision
TABLE OF CONTENTS 91
*255OPC! specific command string; the first one right after the !, and the
last one should go after the closing quotation mark. No space
in between>
Above example can be interpreted as follows: (*) Starting the command code (255)
Router ID is 255 (OP) Output Extender command transmission on (O01) Output 01
Extender, (@001) at baud rate 4800 (!) take the command. Once communication port is
open, command "21 89 01 50 57 30 0A 0D " can be sent. After receiving feedbacks
from AV devices, close the port *255OPC!
For a complete list of command characters and their functions, see examples below.
Example:
Command Codes Action
*255OPO01@001! Open communication port with a device that is
connected to Output #2 Extender at 4800 bps baud
rate
O01“abcdefg Send command (abcdefg) to output #1
*255OPC! Close communication port
*255OPO02-06@004! Open communication port with a device that are
connected to Output #2 ~ 6 Extender at 19200 bps
baud rate
*255OPO05@004,O07@008!
Open communication port with a device that is
connected to Output #5 at 19200 bps baud rate and
Output #7 at 115200 baud rate
OALL"pm " Send command (pm) to all open ports
O02"purelink " Send command (purelink) to output #2
O01-04"pm-256x " Send command (pm-256x) to output #1 ~ 4
OH: 3G/HD-SDI Output Scaler timing select command
The "OH" is an initiation command for 3G/HD-SDI Output Scaler timing selection. The
characters and numbers that follow the "OH" command tell the system, set scaling
timing on selected Output. The last character “!” is found at the end of a command code
which tells the system to execute the command. For a complete list of command
characters and their functions, see examples below.
OH command only applies 3G/HD-SDI Output boards