Ex 1) Command (Connect Input 1 to Output 1)
*255CI01O01!
Ack value
*255sC I01O01!
Ex 2) Command (Check Input connection status on Output 3)
*255?O03!
Ack Value
*255s? I03O03!
General Rules for Command Codes
The commands are coded in ASCII and HEXA. Please refer to Table 5.1 on pg.72 for
detailed descriptions of keys and functions. A basic command code setup is shown below;
Ex) *255CI01O01!
Start + Router ID + Command + Input number + Output number + End + Enter
( * ) ( 255 ) ( C ) ( I01 ) ( O01 ) ( ! ) ( )
▶ A command line allows execution of only one command. Multiple commands require
execution of multiple strings; one command per string.
▶ All commands begin with * (Start) byte.
▶ All commands end with ! (End) byte.
▶ All commands will be executed when (Enter) is entered.
▶ The correct Router ID must be entered in a command code. Systems will not react to the
command if a wrong Router ID is entered. The factory default Router ID is set to 255 and
the universal Router ID is 999. Systems will react to the command whenever universal
Router ID is entered in command code.
▶ Command codes typically are not case-sensitive.
▶ To specify multiple Inputs and Outputs, enter a “,” (Comma) between numbers.
(Ex., *255CI01O01,02,03! : Connects Input 01 to Output 01, 02, and 03)
▶ Use - (Hyphen) for range connection.
(EX., *255CI01O01-04! : Connects Input 01 to Output 01,02,03, and 04)
Table 5.1 Command Codes Characters Table
The table below shows command code characters (keys), which are used to generate control
commands, their functions, and short function descriptions.